A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of retention time indices for comprehensive multidimensional gas chromatography and application to ignitable liquid residue mapping in wildfire investigations. | LitMetric

In this study, we introduce a simple three-step workflow for a universally applicable RI system, to be used in GC×GC analysis of ignitable liquid residue (ILR) for arson investigations. The proposed RI system applies a combination of two well-established GC RI systems: non-isothermal Kovats (K) index in the first dimension and Lee (L) index in the second dimension. The proposed KLI RI system showed very good correlations when compared with predicted values and existing RI systems (r = 0.97 in first dimension, r = 0.99 in second dimension) and was valid for a wide range of analyte concentrations and operational settings (coefficient of variance (CV) < 1% in first dimension, < 10% in second dimension). Using the KLI RI, an ILR classification contour map was created to assist with the identification of ILR types within ASTM E1618. The contour map was successfully applied to neat fuels and a fire scene sample, highlighting the application to wildfire investigation. Standardizing the RI process and establishing acceptable error margins allows the exploration and comparison of comprehensive data generated from GC×GC analysis of ILRs regardless of location, time, or system, further enhancing comprehensive and tenable chemometric analyses of samples. Overall, the KLI workflow was inexpensive, quick to apply, and user-friendly with its simple 3-step design.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2020.461717DOI Listing

Publication Analysis

Top Keywords

second dimension
12
ignitable liquid
8
liquid residue
8
gc×gc analysis
8
contour map
8
dimension
6
development retention
4
retention time
4
time indices
4
indices comprehensive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!