Purpose: Flow-based arterial spin labeling (ASL) techniques provide a transit-time insensitive alternative to the more conventional spatially selective ASL techniques. However, it is not clear which flow-based ASL technique performs best and also, how these techniques perform outside the brain (taking into account eg, flow-dynamics, field-inhomogeneity, and organ motion). In the current study we aimed to compare 4 flow-based ASL techniques (ie, velocity selective ASL, acceleration selective ASL, multiple velocity selective saturation ASL, and velocity selective inversion prepared ASL [VSI-ASL]) to the current spatially selective reference techniques in brain (ie, pseudo-continuous ASL [pCASL]) and kidney (ie, pCASL and flow alternating inversion recovery [FAIR]).

Methods: Brain (n = 5) and kidney (n = 6) scans were performed in healthy subjects at 3T. Perfusion-weighted signal (PWS) maps were generated and ASL techniques were compared based on temporal SNR (tSNR), sensitivity to perfusion changes using a visual stimulus (brain) and robustness to respiratory motion by comparing scans acquired in paced-breathing and free-breathing (kidney).

Results: In brain, all flow-based ASL techniques showed similar tSNR as pCASL, but only VSI-ASL showed similar sensitivity to perfusion changes. In kidney, all flow-based ASL techniques had comparable tSNR, although all lower than FAIR. In addition, VSI-ASL showed a sensitivity to B -inhomogeneity. All ASL techniques were relatively robust to respiratory motion.

Conclusion: In both brain and kidney, flow-based ASL techniques provide a planning-free and transit-time insensitive alternative to spatially selective ASL techniques. VSI-ASL shows the most potential overall, showing similar performance as the golden standard pCASL in brain. However, in kidney, a reduction of B -sensitivity of VSI-ASL is necessary to match the performance of FAIR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7898485PMC
http://dx.doi.org/10.1002/mrm.28603DOI Listing

Publication Analysis

Top Keywords

asl techniques
36
flow-based asl
20
selective asl
16
asl
15
techniques
12
spatially selective
12
velocity selective
12
brain kidney
12
flow-based arterial
8
arterial spin
8

Similar Publications

Background: Chronic kidney disease (CKD) presents a significant global health challenge. Nephrology nurses, possessing specialized competencies, play an essential role in providing high-quality care to CKD patients.

Aim: This scoping review aims to comprehensively map and synthesize literature on the competencies of nephrology nurses worldwide.

View Article and Find Full Text PDF

Background And Aim: The aim of the present study was to evaluate the prevalence and to identify the independent predictors of multi-drug resistance among a cohort of patients admitted to emergency department for urinary tract infections (UTI), and to assess the impact of antimicrobial resistance on the clinical outcomes.

Methods: We conducted a prospective multicentre study enrolling all adult patients admitted to one of the eight emergency departments participating in the study with a microbiologically confirmed diagnosis of UTI from February 2023 to July 2024. The primary outcome evaluated was 30-day mortality; secondary outcomes included 7-day mortality and clinical response.

View Article and Find Full Text PDF

Introduction: Screening for nasal carriage of Staphylococcus (S.) aureus is associated with a reduction of peritoneal dialysis (PD)-related infections, but conflicting results have questioned the benefit of this practice. This study evaluated the clinical effectiveness of the screening program for nasal carriage of S.

View Article and Find Full Text PDF

A signal energy approach of acoustic source localization in plate structures using a discrete sensor array.

Ultrasonics

December 2024

Department of Civil and Architectural Engineering and Mechanics, University of Arizona, Tucson, AZ 85721, USA; Aerospace and Mechanical Engineering Department, Materials Science and Engineering Department, University of Arizona, Tucson, AZ 85721, USA.

In the field of engineering structural health monitoring, acoustic source localization (ASL) is a common method to monitor early damage. Most of the existing ASL techniques have high requirements for accurate acquisition of time of arrival, and require complex iterative algorithms or signal processing techniques, which are not conducive to real-time monitoring. In this paper, a signal energy approach of acoustic source localization in plate structures using a discrete sensor array is proposed.

View Article and Find Full Text PDF

the present multicenter retrospective study aimed to evaluate the efficacy and safety of intra-class switching between interleukin-17A (IL-17A) inhibitors, specifically from ixekizumab to secukinumab, in patients with plaque psoriasis. this study included 11 patients (6 male, 5 female) who had previously received ixekizumab and then were switched to secukinumab. Patients' PASI, DLQI, and pain VAS (in those with psoriatic arthritis) were evaluated at weeks 16, 24, 54, and 98.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!