A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraprocedural dynamics of cardiac conduction during transcatheter aortic valve implantation: Assessment by simultaneous electrophysiological testing. | LitMetric

Background: Transcatheter aortic valve implantation (TAVI) is an established treatment for patients with severe aortic stenosis and high to intermediate surgical risk. However, the proximity of the conduction system to the prosthesis landing zone bears the risk of atrioventricular conduction disorders. The underlying pathophysiology is not fully understood.

Objective: The purpose of this study was to characterize the impact of TAVI on the conduction system as assessed by simultaneous electrophysiological testing.

Methods: AH and HV intervals and QRS duration were measured using a quadripolar His catheter and surface electrocardiogram in 108 patients at baseline (BL), after balloon predilation (timepoint 1 [T1]), after implantation of the valve prosthesis (T2), and after postdilation, if deemed necessary (T3).

Results: Between BL and T2, significant increases of HV interval and QRS duration were observed, with a mean delta of +12.4 ms and +32.7 ms, respectively. Both balloon predilation and valve implantation had an impact on infranodal conduction. No significant increase of AH intervals was documented. The increase of QRS duration led to left bundle branch block (LBBB) in 57 patients (52.8%). Implantation depth positively correlated with QRS prolongation (ρ = 0.21, P = .042) but not with changes of AH or HV interval (ρ = -0.03, P = .762; and ρ = 0.15, P = .130, respectively).

Conclusion: Electrophysiological testing during TAVI shows impairment of infranodal atrioventricular conduction by balloon predilation and valve implantation. This impairment is positively correlated with valve implantation depth and results in an increase of QRS duration with mainly LBBB pattern on surface electrocardiogram.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2020.10.018DOI Listing

Publication Analysis

Top Keywords

valve implantation
20
qrs duration
16
balloon predilation
12
transcatheter aortic
8
aortic valve
8
simultaneous electrophysiological
8
electrophysiological testing
8
conduction system
8
atrioventricular conduction
8
surface electrocardiogram
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!