Objective: To determine the mechanism of growth inhibition of Aggregatibacter actinomycetemcomitans by Maillard reaction products (MRP).

Design: Growth and cell viabilities in the presence or absence of MRP were measured for both the rough and smooth variants of the bacteria. Effects of addition of ferrous and ferric ions on the inhibition of the bacteria by MRP were determined.

Results: MRPs decreased the extent of complex formation of Chrome Azurol S with iron suggesting that MRPs can chelate iron effectively. The chelation causes growth inhibition of both the rough and smooth strains. At low concentrations of the inhibitor, lag time was extended by approximately 12 h while at high concentrations, cells were killed, decreasing cell viability by up to 8 orders of magnitude. Growth of both the rough and smooth strains could be restored to original level by addition of iron. For the rough strain, both ferrous and ferric ions could relieve the inhibition by MRP while for the smooth strain only ferrous ion was effective.

Conclusion: MRPs inhibit the growth of A. actinomycetemcomitans by chelating iron and the inhibition can be relieved by addition of iron.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.archoralbio.2020.104989DOI Listing

Publication Analysis

Top Keywords

rough smooth
12
maillard reaction
8
reaction products
8
aggregatibacter actinomycetemcomitans
8
actinomycetemcomitans chelating
8
chelating iron
8
growth inhibition
8
ferrous ferric
8
ferric ions
8
smooth strains
8

Similar Publications

Influence of Periodically Varying Slit Widths on Sound Absorption by a Slit Pore Medium.

Materials (Basel)

December 2024

School of Engineering and Innovation, The Open University, Milton Keynes MK7 6AA, UK.

A simple pore microstructure of parallel, identical, and inclined smooth-walled slits in a rigid solid, for which prediction of its geometrical and acoustic properties is straightforward, can yield useful sound absorption. This microstructure should be relatively amenable to 3D printing. Discrepancies between measurements and predictions of normal incidence sound absorption spectra of 3D printed vertical and slanted slit pore samples have been attributed to the rough surfaces of the slit walls and uneven slit cross-sections perpendicular to the printing direction.

View Article and Find Full Text PDF

In this study, the response surface methodology was first utilized to optimize the enzyme treatment conditions as reaction pH, temperature, time and enzyme dosage of 9.5, 45 °C, 94.5 min and 100 U/L.

View Article and Find Full Text PDF

People often associate roughness with difficulty, as a figure of speech. Studies have shown that there is a metaphorical connection between the concept of rough versus smooth feel and the degree of difficulty. However, it has not been determined whether rough and smooth tactile experiences influence judgments of perceived task difficulty from the perspective of physical metaphors.

View Article and Find Full Text PDF

The Staining Susceptibility and Surface Roughness of Teeth Restored by Microabrasion and Resin Infiltration: An In Vitro Study.

Polymers (Basel)

December 2024

Department of Restorative Dentistry, Faculty of Dentistry, Thammasat University, 99 M. 18, Paholyothin Road, Klong Luang, Pathum Thani 12120, Thailand.

This study assessed the susceptibility to staining and surface roughness of white-spot lesions (WSLs) treated with resin infiltration (RIT) and microabrasion (MA) under simulated aging through thermocycling in red wine. Seventy-eight extracted human premolars with artificial WSLs were divided into three groups: untreated WSLs (control), RIT-treated (ICON, DMG), and MA-treated (Opalustre, Ultradent). Each group was further split: one subgroup immersed in artificial saliva and the other thermocycled in red wine.

View Article and Find Full Text PDF

Study on the Abrasive Blasting Mechanism of Solder Welded 304V Wire in Vascular Intervention.

Micromachines (Basel)

November 2024

Department of Vascular Surgery, General Surgery Clinical Center, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, 100 Haining Road, Shanghai 200080, China.

The solder burrs on the 304V wire surface can easily scratch the vascular tissue during interventional treatment, resulting in complications such as medial tears, bleeding, dissection, and rupture. Abrasive blasting is often used to remove solder burr and obtain a smooth surface for the interventional device. This study conducted an abrasive blasting experiment to explore the effects of process parameters (air pressure, lift-off height, abrasive volume, and abrasive type) on processing time, surface roughness, and mechanical properties to reveal the material removal mechanism.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!