Background: The construction of multichannel micro-electrode arrays (MEA) generally requires complex and expensive procedures. Here we describe a simple, cheap, flexible method of linear MEA construction.
New Method: Our method allows manufacture of linear MEA (cross section ∼ 375 × 250 μm with 12 electrodes) of any desired length, with customized spacing of the electrode tips (down to a minimum spacing of 200 μm or less) to suit different needs and experiments. We describe the following steps: (1) set-up for MEA construction; (2) building of a construction jig; (3) building the reference, ground and optional electrical stimulation electrodes; (4) treatment of the main recording microwires; (5) soldering of the microwires to the main connector plug and arrangement of the microwires in a customizable array; and (6) testing of the MEA resistance and correct connections. Finally, we describe methods for quick surgical implantation of multiple MEAs and bipolar micro-stimulation electrodes for in vivo experiments in free-moving rats.
Results: We provide examples of multi-site local field potentials from prolonged recordings in awake and free-moving rodents, with recordings viable for months, as well as samples of electrical stimulation effects on cortical and hippocampal recordings. Hippocampal recordings showed clear phase reversal and amplitude changes across its layers.
Conclusions: We briefly discuss how the arrays can support other forms of stimulation such as optogenetic probes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jneumeth.2020.109011 | DOI Listing |
Molecules
November 2024
Department of Chemistry, Technical University of Denmark, Kemitorvet 206, 2800 Kongens Lyngby, Denmark.
A recent broadband rotational spectroscopic investigation of the cross-association mechanisms of CO with monoethanolamine (MEA) in molecular beams [F. Xie et al., , , , e202218539] revealed an intriguing affinity of CO to the hydroxy group.
View Article and Find Full Text PDFJ Chromatogr A
December 2024
Key Laboratory of Rare Earths, Ganjiang Innovation Academy, Chinese Academy of Sciences, Ganzhou 341000, China. Electronic address:
A homogeneous liquid-liquid microextraction technique based on switchable deep eutectic solvent (SDES-HLLME), combined with gas chromatography-triple quadrupole tandem mass spectrometry (GC-MS/MS), was developed for the extraction and analysis of 16 polychlorinated biphenyls (PCBs) in water samples. CO-responsive switchable deep eutectic solvent (SDES), which consists of monoethanolamine (MEA) being used as a hydrogen bond acceptor (HBA) and 3-methoxyphenol (3-MP) being used as a hydrogen bond donor (HBD), was used as the extractant, thus providing an environmentally friendly alternative to conventional toxic organic solvents. The study systematically investigated the effects of various parameters on extraction efficiency, including the type and volume of SDES, vortexing duration, CO bubbling time, centrifugation rate and time, ionic strength.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
December 2024
Therapeutics Development and Supply, Analytical Development - Janssen Research & Development, LLC, Malvern, PA, USA.
Bispecific antibodies have a wide range of applications in cancer immunotherapy, some of which are manufactured by controlled Fab-arm exchange requiring the reductant 2-mercaptoethylamine (2-MEA). As a process impurity, monitoring the residual 2-MEA in bispecific antibody drug product process development is needed. A novel reversed phase-high performance liquid chromatography (RP-HPLC) method for measurement of residual 2-MEA that uses 7-fluorobenzofurazan-4-sulfonic acid ammonium salt (SBD-F) as a fluorescent-detection tag in drug product formulations containing high concentrations of arginine has been developed.
View Article and Find Full Text PDFACS Appl Mater Interfaces
November 2024
Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75080, United States.
The design and characterization of thin-film ribbon cables as electrical interconnects for implanted neural stimulation and recording devices are reported. Our goal is to develop flexible and extensible ribbon cables that integrate with thin-film, cortical penetrating microelectrode arrays (MEAs). Amorphous silicon carbide (a-SiC) and polyimide were employed as the structural elements of the ribbon cables and multilayer titanium/gold thin films as electrical traces.
View Article and Find Full Text PDFTumori
December 2024
Laboratorio di Bioinformatica e Biostatistica, IRCCS Istituto Tumori Giovanni Paolo II, Bari, Italy.
Background: Literature is lacking when it comes to oncology nursing attitudes in clinical trial involvement.
Objective: To assess how Italian oncology nurses perceived their attitudes in clinical trials involvement.
Methods: An on-line cohort observational study was carried out.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!