Integrated nanoparticle size with membrane porosity for improved analytical performance in sandwich immunochromatographic assay.

Anal Chim Acta

State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China; School of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China; Jiangxi-OAI Joint Research Institute, Nanchang University, Nanchang, 330047, PR China. Electronic address:

Published: January 2021

The use of luminescent nanobeads to improve the sensitivity of sandwich immunochromatographic assay (ICA) has obtained increasing concern. Illustrating the relationship among luminescent intensity, nanobead size, nitrocellulose membrane aperture, and ICA sensitivity is important for achieving the optimal target detection. Thus, we synthesized six differently sized quantum dot beads (QBs) (95, 140, 180, 235, 325, and 405 nm) as ICA labels and applied them in three aperture membranes (10, 15, and 25 μm). Results indicate that increasing the QB size to less than an appropriate size of 235 nm is beneficial for ICA sensitivity because of the increased fluorescence. However, oversized QBs result in reduced sensitivity due to the decreased diffusion or settlement of the QB on the membrane that causes obvious background signal. The small aperture membrane perfectly matching the QB size contributes to ICA sensitivity by decreasing the migration velocity of the QB probe for increased binding of the QB@analyte complex at the T zone. Consequently, the best detection of hepatitis B surface antigen with a sensitivity of 0.156 ng/mL is achieved using 235 nm QBs in 15 μm membrane. Further performance evaluation of our QB-ICA demonstrates excellent accuracy, selectivity, and practicability. This work provides a new idea to manipulate the sensitivity of sandwich ICA by tuning the QB size and the membrane aperture, and a theoretical guidance for selecting the probe and membrane to achieve the best detection of target analytes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2020.10.041DOI Listing

Publication Analysis

Top Keywords

ica sensitivity
12
size membrane
8
sandwich immunochromatographic
8
immunochromatographic assay
8
sensitivity sandwich
8
membrane aperture
8
best detection
8
membrane
7
sensitivity
7
size
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!