Value of Galectin-3 assay in children with heart failure secondary to congenital heart diseases: a prospective study.

BMC Pediatr

Pediatric Cardiology Unit, Department of Pediatrics, Faculty of Medicine, Mansoura University, Mansoura, Egypt.

Published: November 2020

Background: Galectin-3 is a new biomarker, which plays an important role in tissue inflammation, cardiac remodeling, and fibrosis. It can be readily measured in the circulation to detect early heart failure (HF). This study aimed to assess the value of galectin-3 assay in early diagnosis of children with heart failure secondary to congenital heart disease (CHD) and correlate it with the patients' outcome.

Methods: This prospective cohort study included 75 children diagnosed to have CHD; {Group A: 45 CHD children with HF symptoms and reduced ejection fraction (REF) and Group B: 30 CHD children with no HF symptoms and normal ejection fraction (NEF)}. They were compared to 40 age- and sex-matched controls (Group C). Children with CHD undergone history taking, Ross HF classification, Echocardiographic assessment and laboratory investigations including serum galactin-3 level.

Results: Galectin-3 serum level increased in CHD children, and it showed significant increase in (Gp A) compared to Gp B or Gp C (p = ≤ 0.001). In addition, serum level of Galactin-3 was correlated positively with Ross classification (r = 0.68, p = 0.018) and negatively correlated to EF% (r= -0.61, p ≤ 0.001). Galactin-3 showed better diagnostic value than Ross HF classification in early diagnosis of HF in CHD children with a cut point (≥ 10.4), significantly had 96.7% sensitivity, 90% specificity, 91% positive predictive value, 93.2% negative predictive value, with area under the curve (AUC = 0.96) and 93% accuracy. While there was a significant correlation between Ross HF classification and HF outcome in (Gp A) children (p = 0.05), we did not find any significant correlation between serum galectin-3 level and HF mortality in same group (p = 0.08).

Conclusions: Galectin-3 assay is a promising marker for early diagnosis of HF in children with CHD; but it has no role in detecting HF mortality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7697383PMC
http://dx.doi.org/10.1186/s12887-020-02427-9DOI Listing

Publication Analysis

Top Keywords

chd children
16
ross classification
16
galectin-3 assay
12
heart failure
12
early diagnosis
12
children
10
children heart
8
failure secondary
8
secondary congenital
8
congenital heart
8

Similar Publications

Exploring Health Educational Interventions for Children With Congenital Heart Disease: Scoping Review.

JMIR Pediatr Parent

January 2025

Department of Design Innovation, College of Design, University of Minnesota, Twin Cities, Minneapolis, MN, United States.

Background: Congenital heart disease (CHD) is the most common birth defect, affecting 40,000 births annually in the United States. Despite advances in medical care, CHD is often a chronic condition requiring continuous management and education. Effective care management depends on children's understanding of their condition.

View Article and Find Full Text PDF

Importance: A recent advisory from the American Heart Association delineated the potential benefits of developmental care for hospitalized children with congenital heart disease (CHD) and a critical gap in research evaluating the association of such inpatient programs with neurodevelopmental outcomes.

Objective: To investigate associations between the Cardiac Inpatient Neurodevelopmental Care Optimization (CINCO) program interventions, delirium, and neurodevelopment in young children (newborn through age 2 years) hospitalized with CHD.

Design, Setting, And Participants: This cohort study used quality improvement data from inpatient cardiac units at a tertiary care children's hospital in the US.

View Article and Find Full Text PDF

Maternal exposure to bisphenol A induces congenital heart disease through mitochondrial dysfunction.

FASEB J

January 2025

Key Laboratory of Birth Defects and Related Diseases of Women and Children of MOE, Department of Pediatrics, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, China.

Congenital heart disease (CHD) represents a major birth defect associated with substantial morbidity and mortality. Although environmental factors are acknowledged as potential contributors to CHD, the underlying mechanisms remain poorly understood. Bisphenol A (BPA), a common endocrine disruptor, has attracted significant attention due to its widespread use and associated health risks.

View Article and Find Full Text PDF

Background: Congenital heart diseases (CHDs) are not rare and often require an intervention at some point of time. Pediatric cardiac catheterization, a minimally invasive procedure, is performed to diagnose and to correct many cardiac abnormalities. Deep sedation with spontaneously breathing patients is the preferred technique for pediatric catheterization in the pediatric population.

View Article and Find Full Text PDF

Purpose: Northwest axis on an electrocardiogram is conventionally thought to be associated with CHD, but there is a paucity of data regarding the types and incidence of CHD associated with this finding. The purpose of this study was to report the types and incidence of CHD found at our institution to determine the efficacy of electrocardiograms as a screening test in infants.

Methods: Retrospective, single-centre study of all infants ≤ 60 days of age who underwent a first-time electrocardiogram from 2015 to 2021.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!