A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Medial stabilised total knee arthroplasty achieves comparable clinical outcomes when compared to other TKA designs: a systematic review and meta-analysis of the current literature. | LitMetric

Purpose: The purpose of this study was to perform a systematic review and meta-analysis to compare clinical and patient-reported outcome measures of medially stabilised (MS) TKA when compared to other TKA designs.

Methods: The Preferred Reporting Items for Systematic Review and Meta-Analyses algorithm was used. The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, and EMCARE databases were searched to June 2020. Studies with a minimum of 12 months of follow-up comparing an MS TKA design to any other TKA design were included. The statistical analysis was completed using Review Manager (RevMan), Version 5.3.

Results: The 22 studies meeting the inclusion criteria included 3011 patients and 4102 TKAs. Overall Oxford Knee Scores were significantly better (p = 0.0007) for MS TKA, but there was no difference in the Forgotten Joint Scores (FJS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Society Score (KSS)-Knee, KSS-Function, and range of motion between MS and non-MS TKA designs. Significant differences were noted for sub-group analyses; MS TKA showed significantly worse KSS-Knee (p = 0.02) and WOMAC (p = 0.03) scores when compared to Rotating Platform (RP) TKA while significantly better FJS (p = 0.002) and KSS-knee scores (p = 0.0001) when compared to cruciate-retaining (CR) TKA.

Conclusion: This review and meta-analysis show that MS TKA designs result in both patient and clinical outcomes that are comparable to non-MS implants. These results suggest implant design alone may not provide further improvement in patient outcome following TKA, surgeons must consider other factors, such as alignment to achieve superior outcomes.

Level Of Evidence: III.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8866298PMC
http://dx.doi.org/10.1007/s00167-020-06358-xDOI Listing

Publication Analysis

Top Keywords

tka designs
12
systematic review
12
review meta-analysis
12
tka
11
clinical outcomes
8
compared tka
8
tka design
8
review
5
medial stabilised
4
stabilised total
4