This work presents an analytical relationship between gradient-spoiled and RF-spoiled steady-state signals. The two echoes acquired in double-echo in steady-state scans are shown to lie on a line in the signal plane, where the two axes represent the amplitudes of each echo. The location along the line depends on the amount of spoiling and the diffusivity. The line terminates in a point corresponding to an RF-spoiled signal. In addition to the main contribution of demonstrating this signal relationship, we also include the secondary contribution of preliminary results from an example application of the relationship, in the form of a heuristic denoising method when both types of scans are performed. This is investigated in simulations, phantom scans, and in vivo scans. For the signal model, the main topic of this study, simulations confirmed its accuracy and explored its dependency on signal parameters and image noise. For the secondary topic of its preliminary application to reduce noise, simulations demonstrated the denoising method giving a reduction in noise-induced standard deviation of about 30%. The relative effect of the method on the signals is shown to depend on the slope of the described line, which is demonstrated to be zero at the Ernst angle. The phantom scans show a similar effect as the simulations. In vivo scans showed a slightly lower average improvement of about 28%.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8817832PMC
http://dx.doi.org/10.1088/1361-6560/abce8aDOI Listing

Publication Analysis

Top Keywords

gradient-spoiled rf-spoiled
8
rf-spoiled steady-state
8
denoising method
8
phantom scans
8
vivo scans
8
scans
6
signal
5
utilizing shared
4
shared gradient-spoiled
4
steady-state mri
4

Similar Publications

This work presents an analytical relationship between gradient-spoiled and RF-spoiled steady-state signals. The two echoes acquired in double-echo in steady-state scans are shown to lie on a line in the signal plane, where the two axes represent the amplitudes of each echo. The location along the line depends on the amount of spoiling and the diffusivity.

View Article and Find Full Text PDF

On the stationary states in gradient echo imaging.

J Magn Reson Imaging

April 1997

Radiology Department, University of Alabama at Birmingham, Alabama 35233, USA.

A formalism is presented that concisely describes the magnetization of a sample subjected to a periodic series of RF pulses. In this formalism, the steady state of the magnetization is shown to be a sum of magnetic substates, each with unique contrast characteristics. When more than one substate contributes to a given image, the substates interfere with each other, producing ghosts and other artifacts.

View Article and Find Full Text PDF

The signal evolution behaviors and corresponding image appearances for different methods of spoiling or refocusing the transverse magnetization in short TR gradient-echo imaging during the approach to steady state were investigated experimentally and using computer simulations based on the Bloch equations. Specifically, ideally spoiled, gradient-spoiled, gradient-refocused, and RF-spoiled pulse sequence configurations were studied. This study showed that, for the gradient-spoiled configuration, the signal evolution is position and phase-encoding order-dependent and, under typical imaging conditions, can deviate substantially from the ideally spoiled signal evolution at some spatial positions, resulting in intensity banding image artifacts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!