In 2015, the National Institute for Occupational Safety and Health (NIOSH) published a draft vapor containment protocol to quantitatively evaluate combined liquid, aerosol, and vapor containment performance of commercially available closed-system drug-transfer devices (CSTDs) that claim to be effective for gas/vapor containment within a controlled test environment. Until the release of this proposed protocol, no standard method for evaluating airtightness of CSTDs existed. The aim of this study was to evaluate six commercially available CSTDs utilizing NIOSH draft protocol methodology to evaluate vapor containment under a robust vapor challenge. In this study, six commercially available CSTDs were tested utilizing draft NIOSH vapor containment protocol methodology to simulate drug compounding and administration using 70% isopropyl alcohol (IPA) as the challenge agent. All device manipulations were carried out in an enclosed test chamber. A Miran sapphIRe gas analyzer was used to detect IPA vapor levels that escaped the device. Study test included the two tasks designated by the NIOSH protocol, with additional steps added to the evaluation. Tasks were repeated 10 times for each device. Only three of the six tested CSTDs (Equashield®, HALO®, and PhaSealTM) had an average IPA vapor release below the quantifiable performance threshold (1.0 ppm) for all tasks performed. This value was selected by NIOSH to represent the performance threshold for successful containment. The remaining three CSTDs had vapor release above 1 ppm at various times during the IPA manipulation process. Equashield®, HALO®, and PhaSealTM devices tested met the 2015 NIOSH protocol quantifiable performance threshold, functioning as a truly closed system. Quantifiable effective data may be useful in product selection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7672663PMC
http://dx.doi.org/10.1177/0018578719848730DOI Listing

Publication Analysis

Top Keywords

vapor containment
16
performance threshold
12
vapor
9
commercially closed-system
8
closed-system drug-transfer
8
drug-transfer devices
8
draft vapor
8
containment protocol
8
commercially cstds
8
protocol methodology
8

Similar Publications

Introduction: The purpose of this study was to assess and compare the effectiveness of seven different closed system transfer device (CSTD) product lines following the 2015 NIOSH Vapor Containment Performance Protocol, using a Gasmet™ DX5000 Terra multigas FTIR analyzer.

Methods: Seven different CSTD systems were assessed using a two-task evaluation on their capacity to contain the NIOSH-specified challenge agent, 70% isopropyl alcohol (IPA). Task 1 simulated reconstitution and compounding steps while Task 2 simulated compounding and administration steps.

View Article and Find Full Text PDF

Background has emerged as an important healthcare-associated pathogen that has high mortality rates. Additionally, this pathogen can cause nosocomial outbreaks. However, in comparison to the vast majority of the pathogenic species from the genus Candida, is difficult to treat and identify by using conventional therapeutic and diagnostic modalities.

View Article and Find Full Text PDF

Ultrasonic delamination is a low energy approach for direct recycling of spent lithium-ion batteries. The efficiency of the ultrasonic delamination relies both on the thermophysical properties (such as viscosity, surface tension, and vapour pressure) of the solvent in which the delamination process is carried out, and the properties of the ultrasound source as well as the geometry of the containment vessel. However, the effect of tailoring solutions to optimise cavitation and delamination of battery cathode coatings has not yet been sufficiently investigated.

View Article and Find Full Text PDF

Hydraulic containment of TCE contaminated groundwater using pulsed pump-and-treat: Performance evaluation and vapor intrusion risk assessment.

Environ Pollut

April 2024

Department of Earth and Environmental Sciences, Korea University, 145, Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea. Electronic address:

Article Synopsis
  • This study focuses on the effectiveness of pulsed pump-and-treat technology for managing groundwater contaminated with Trichloroethylene (TCE) at a hypothetical site.
  • Numerical models were employed to simulate groundwater flow and contamination, assessing capture width, removal efficiency, and the risks of TCE leakage during different operational stages.
  • Results indicate that while continuous operation effectively contained TCE, pulsed operation resulted in leakage downstream; some reduction in contamination levels was achieved through biodegradation.
View Article and Find Full Text PDF

This systematic review evaluated preclinical studies to assess whether PBM has a more favorable histological response than other treatments used before delayed replantation of avulsed teeth. This review followed the PRISMA checklist and was registered in PROSPERO. MEDLINE (PubMed), Embase, Scopus and Web of Science were searched from their inception to July 14, 2022.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!