Purpose: Our primary purpose was to evaluate the reliability of telephone administration of the Patient-Reported Outcomes Measurement Information System (PROMIS) Upper Extremity (UE) Computer Adaptive Test (CAT) version 2.0 in a hand and upper extremity population, and secondarily to make comparisons with the abbreviated version of the Disabilities of the Arm, Shoulder, and Hand (QuickDASH).
Methods: Patients more than 1 year out from hand surgeries performed at a single tertiary institution were enrolled. Half of the patients completed telephone PROMIS UE CAT and QuickDASH surveys first, followed by computer-based surveys 1 to 10 days later, and the other half completed them in the reverse order. Telephone surveys were readministered 2 to 6 weeks later to evaluate test-retest reliability. Concordance correlation coefficients (CCCs) were used to assess agreement between telephone and computer-based scores, and intraclass correlation coefficients (ICCs) were used to assess test-retest reliability. The proportion of patients with discrepancies in follow-up scores that exceeded estimates of the minimal clinically important difference (MCID) was evaluated.
Results: For the 89 enrolled patients, the PROMIS UE CAT CCC was 0.82 (83% confidence interval [83% CI], 0.77-0.86; good), which was significantly lower than 0.92 (83% CI, 0.89-0.94; good to excellent) for the QuickDASH. The PROMIS UE CAT ICC did not differ significantly from the QuickDASH (0.85 and 0.91, respectively). Differences in telephone versus computer scores exceeded 5 points (MCID estimate) for the PROMIS UE CAT in 34% of patients versus 5% of patients exceeding 14 points (MCID estimate) for the QuickDASH.
Conclusions: Significantly better reliability was observed for the QuickDASH than the PROMIS UE CAT when comparing telephone with computer-based score acquisition. Over one-third of patients demonstrated a clinically relevant difference in scores between the telephone and the computer-administered tests. We conclude that the PROMIS UE CAT should only be administered through computer-based methods.
Clinical Relevance: These findings suggest that differences in collection methods for the PROMIS UE CAT may systematically affect the scores obtained, which may erroneously influence the interpretation of postoperative scores for hand surgery patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7935760 | PMC |
http://dx.doi.org/10.1016/j.jhsa.2020.09.014 | DOI Listing |
J Bone Joint Surg Am
December 2024
Department of Orthopaedic Surgery, University of Utah, Salt Lake City, Utah.
Background: There is no standardization within hand and upper-extremity surgery regarding which patient-reported outcome measures (PROMs) are collected and reported. This limits the ability to compare or combine cohorts that utilize different PROMs. The aim of this study was to develop a linkage model for the QuickDASH (shortened version of the Disabilities of the Arm, Shoulder and Hand) and PROMIS PF CAT (Patient-Reported Outcomes Measurement Information System Physical Function computerized adaptive testing) instruments to allow interconversion between these PROMs in a hand surgery population.
View Article and Find Full Text PDFHealth Qual Life Outcomes
December 2024
Department of Psychiatry, Psychotherapy, Psychosomatics, and Medical Psychology, BA, University Clinic of Psychiatry II, Innsbruck Medical University, Anichstraße 35, Innsbruck, A-6020, Austria.
Background: To assess fatigue in cancer patients, several patient-reported outcome measures (PROMs) are available that differ in content. To support the selection of suitable measures for specific applications and to evaluate possibilities of quantitative linking, the present study provides a content comparison of common fatigue measures, scales, and item banks. We included the EORTC CAT Core, EORTC QLQ-FA12, EORTC QLQ-C30, FACIT-F, PROMIS Fatigue (Cancer item bank v1.
View Article and Find Full Text PDFJ Patient Rep Outcomes
October 2024
Department of Epidemiology and Data Science, Amsterdam UMC Location Vrije Universiteit, Amsterdam, The Netherlands.
Background: The commonly used ('legacy') PROMs evaluating outcomes of total hip arthroplasty (THA), have several limitations regarding their measurement properties and interpretation of scores. One innovation in PROMs is the use of Computerized Adaptive Testing (CAT). The Patient-Reported Outcomes Measurement Information System (PROMIS) is a validated system of CATs.
View Article and Find Full Text PDFBackground: The Optimal Screening for Prediction of Referral and Outcome Yellow Flag (OSPRO-YF) Tool is a 10-item multidimensional screening tool utilized to evaluate pain-related psychological traits in individuals with musculoskeletal pain conditions. The validity of postoperatively collected OSPRO-YF is unclear. This study sought to assess validity of the OSPRO-YF by comparing it to patient-reported outcome scores in both preoperative and postoperative settings.
View Article and Find Full Text PDFFront Neurol
July 2024
Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, MA, United States.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!