A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of enamel loss by scanning electron microscopy after debonding brackets place with four different adhesives. | LitMetric

Evaluation of enamel loss by scanning electron microscopy after debonding brackets place with four different adhesives.

Microsc Res Tech

Facultad de Odontología, Campus de Ciencias de la Salud, Universidad Autónoma de Yucatán, Calle 61-A num 492-A, Centro, Mérida, Yucatán, 97000, Mexico.

Published: May 2021

The clinically adequate shear bond strengths (SBS) should be from 2.8 to 10 MPa. The aim of this research is to observe tooth enamel loss through a scanning electron microscope (SEM) during the debonding of braces of four adhesive systems. Then, 100 premolars were used in 4 groups of 25 specimens each, for Transbond MIP (G1), Enlight (G2), Stylus (G3), and Transbond Plus SEP (G4). The research was done under the NOM ISO/TS 11405:2015. Gemini 3M were placed under the manufacturer's recommendations. The SBS test was done at 24 hr in an Instron electromechanical universal testing machine at 1 mm/1 min. Adhesive remnant index (ARI) was measured, all of the brackets where examined in the SEM. For the shear bonding strength G1 = 10.09 ± 2.73 MPa, G2 = 9.27 ± 3.99 MPa, G3 = 7.83 ± 4.46 MPa, and G4 = 6.40 ± 2.85 MPa statistically significant differences were found when comparing the four groups (p = .002). In the Tukey post hoc test, G1 versus G4 and G2 versus G4, statistically significant differences were found. For the ARI a value of 1 in 46%, followed by a value of 2 in 38%, a value of 3 in 13% and a value of 0 in 3% of the total samples, finding statistically significant differences (p < .001). In relation to the tooth enamel loss due to SBS, statistically significant differences were found (p = .326). G1 and G4 had not statistically significant differences. Even though our results concur with the appropriate clinical values, we observed tooth enamel loss with Transbond Plus SEP and Stylus.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jemt.23652DOI Listing

Publication Analysis

Top Keywords

statistically differences
20
enamel loss
16
tooth enamel
12
loss scanning
8
scanning electron
8
transbond sep
8
statistically
5
differences
5
evaluation enamel
4
loss
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!