Background: Gender-affirming therapy with testosterone is commonly prescribed to aid in the masculinization of transgender men. Sex-hormone concentrations are routinely measured, but interpretation of results can be difficult due to the lack of published reference intervals.

Methods: Healthy transgender individuals who had been prescribed testosterone (n = 82) for at least a year were recruited from internal medicine and primary care clinics that specialize in transgender medical care. Total testosterone and estradiol were measured using immunoassay and mass spectrometry; LH, FSH, SHBG, prolactin, progesterone, anti-Müllerian hormone (AMH), and dehydroepiandrosterone sulfate (DHEAS) were measured using immunoassay; free testosterone was calculated. Reference intervals (central 95%) were calculated according to Clinical Laboratory Standards Institute guidelines.

Results: When evaluating general endocrine laboratory tests in people using masculinizing hormones, reference intervals for cisgender men can be applied for total and free testosterone and SHBG and reference intervals for cisgender women can be applied for prolactin. Reference intervals for estradiol, LH, FSH, AMH, and DHEAS differ from those used for cisgender men and cisgender women, and therefore should be interpreted using intervals specific to the transmasculine population. For testosterone and estradiol, results from immunoassays were clinically equivalent to mass spectrometry.

Conclusion: Masculinizing hormones will alter the concentrations of commonly evaluated endocrine hormones. Providers and laboratories should use appropriate reference intervals to interpret the results of these tests.

Download full-text PDF

Source
http://dx.doi.org/10.1093/jalm/jfaa169DOI Listing

Publication Analysis

Top Keywords

reference intervals
24
transgender men
8
testosterone estradiol
8
measured immunoassay
8
free testosterone
8
masculinizing hormones
8
intervals cisgender
8
cisgender men
8
cisgender women
8
reference
7

Similar Publications

Tunable Characteristics of Optical Frequency Combs from InGaAs/GaAs Two-Section Mode-Locked Lasers.

Sensors (Basel)

December 2024

School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.

We observed tunable characteristics of optical frequency combs (OFCs) generated from InGaAs/GaAs double quantum wells (DQWs) asymmetric waveguide two-section mode-locked lasers (TS-MLLs). This involves an asymmetric waveguide mode-locked semiconductor laser (AWML-SL) operating at a center wavelength of net modal gain of approximately 1.06 µm, which indicates a stable pulse shape, with the power-current(P-I) characteristic curve revealing a small difference between forward and reverse drive currents in the gain region.

View Article and Find Full Text PDF

Assessing Protein Content and Dimer Formation in the Bevacizumab Reference Product and Biosimilar Versions Marketed in Spain.

Pharmaceutics

November 2024

Departamento de Ingeniería Química y Tecnología Farmacéutica, Facultad de Farmacia, Universidad de La Laguna, Avda. Fco. Sánchez, s/n, 38200 Santa Cruz de Tenerife, Spain.

Background: The manufacture of biologics is a complex, controlled, and reproducible process that results in a product that meets specifications. This should be based on data from batches used to demonstrate manufacturing consistency. Ten batches of originator product (Avastin) were analyzed over a 10-year period.

View Article and Find Full Text PDF

: To obtain bioelectrical data to assess nutritional status for extremely low-birth-weight (ELBW) infants upon reaching term-corrected age. : A descriptive, observational, prospective, and single-center study, which included ELBW preterm infants was performed. The study variables collected were gestational age, sex, and anthropometry at birth and at term-corrected age.

View Article and Find Full Text PDF

Diagnostic Accuracy of Antigen-Based Skin Tests (TBSTs) for Tuberculosis Infection Compared with TST and IGRA: A Network Meta-Analysis.

Pathogens

November 2024

Yunnan Province Key Laboratory of Children's Major Diseases Research, School of Basic Medical Sciences, Kunming Medical University, Kunming 650500, China.

The aim of this study was to evaluate the diagnostic accuracy of the IGRA, TST, and TBST by combining diagnostic test accuracy (DTA) analysis and network meta-analysis (NMA) to increase the reliability and accuracy of diagnostic methods and promote the eradication of TB. An electronic search of the PubMed, Embase, and Cochrane databases was conducted, from the date of establishment to September 30, 2024. Data were synthesized with frequentist random-effects network meta-analyses, a single-group rate meta-analysis algorithm, and a bivariate mixed-effects logistic regression model.

View Article and Find Full Text PDF

Little is known about the clinical characteristics and pathogens causing hospital-acquired bloodstream infections (HA-BSIs) in relation to an intensive care unit (ICU) stay. Population-based cohort study, comprising 35% of the Danish population, 2009-2016. We derived four patient groups with first-time HA-BSIs: no ICU stay during the admission (non-ICU patients) and HA-BSI acquired before, in, or after an ICU stay (before-ICU, in-ICU, and after-ICU patients).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!