Objective: Tonsillectomy is one of the most common surgeries performed in the pediatric population. Although different forms of instruments and various methods are used to perform tonsillectomy, none of them is still recognized as the best global technique. This study aimed to compare the outcomes of the new Bipolar Loop tonsillectomy versus bipolar diathermy technique.

Methods: This study is a pilot randomized clinical trial and was conducted on 40 pediatric patients who were the candidate of tonsillectomy. Patients were divided into two groups of Bipolar Loop or bipolar diathermy. Operation time, intraoperative bleeding, tonsillar fossa wound, postoperative complications, and duration of return to normal diet were evaluated in the current study.

Results: In both of the Bipolar Loop and bipolar diathermy groups, no significant difference was found in terms of sex, age, and weight. The average amount of the operative time, intra-operative blood loss, and postoperative pain loss were significantly less in the Bipolar Loop group (P < .001). In addition, the tonsillar fossa wound healing scores were significantly better (on the 14th day, P = 0.009). However, there was no significant difference between the two groups in terms of postoperative bleeding, duration of return to a normal diet, and postoperative symptoms of fever, otalgia, or voice change between the groups.

Conclusion: The study showed that blood loss and postoperative pain through day 7 were significantly less in the Bipolar Loop group. Tonsillectomy with Bipolar Loop can be recommended as one of the methods for tonsillectomy, especially in pediatric patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijporl.2020.110505DOI Listing

Publication Analysis

Top Keywords

bipolar loop
20
bipolar diathermy
16
bipolar
9
versus bipolar
8
pilot randomized
8
loop bipolar
8
tonsillectomy
5
loop device
4
device versus
4
diathermy
4

Similar Publications

Study Objective: To determine the association of repeat polypectomy with patient and/or polyp characteristics, surgical setting, and type of hysteroscopic equipment.

Methods: Retrospective cohort study including all women who had undergone operative hysteroscopy for the removal of endometrial polyps between 1/2012-12/2022 in our division. Operative hysteroscopy with resection of endometrial polyps was performed using a bipolar loop resectoscope, miniaturized hysteroscopic instruments (bipolar needle, scissors, and graspers), or a tissue-removal device (from April 2021), with or without general anesthesia.

View Article and Find Full Text PDF

Genes involved in regulating the hypothalamic-pituitary-adrenal (HPA) axis, including the glucocorticoid receptor (GR), are linked to various stress-related psychopathologies including bipolar disorder as well as other mood and trauma-related disorders. The protein product of the cell cycle gene, is a GR interaction partner in peripheral cells. However, the precise roles of SKA2 in stress and GR signaling in the brain, specifically in nonreplicating postmitotic neurons, and its involvement in HPA axis regulation remain unclear.

View Article and Find Full Text PDF

This study presents an innovative dual closed-loop DC control system for intelligent electric vehicle (EV) charging infrastructure, designed to address the challenges of high power factor, low harmonic pollution, and high efficiency in EV charging applications. The research implements a three-level Pulse Width Modulation (PWM) rectifier with a diode-clamped topology and Insulated-Gate Bipolar Transistors (IGBTs), achieving a power factor of 0.99, a total harmonic distortion (THD) of 1.

View Article and Find Full Text PDF

Background: Prostate cancer (PCa) is a public health problem mostly reported in developed countries. The androgen receptor (AR) regulates the development and physiological function of normal prostate as well as the proliferation of cancerous prostate tissue. Treatment with supraphysiological androgen levels (SAL) is used in bipolar androgen therapy and inhibits PCa growth, suggesting SAL induces a tumor suppressive program.

View Article and Find Full Text PDF

Comprehensive analysis of faults and diagnosis techniques in cascaded multi-level inverters.

Heliyon

November 2024

Laboratory of Technology and Applied Sciences, University Institute of Technology, University of Douala, PO Box: 8698, Douala, Cameroon.

Reliability is a crucial factor to consider for multi-level inverters (MLIs) used in industrial applications. With the increasing number of power semiconductor devices, the potential for defects to significantly degrade the overall system is heightened. A highly effective fault-detection technique is required to minimize the impact of faults.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!