This study aimed to assess muscle wasting and risk of protein energy wasting (PEW) in hemodialysis (HD) patients using an ultrasound (US) imaging method. PEW was identified using the ISRNM criteria in 351 HD patients. Quadriceps muscle thickness of (RF) and (VI) muscles and cross-sectional area (CSA) of the RF muscle (RF) were measured using US and compared with other physical measures. Associations of US indices with PEW were determined by logistic regression. Irrespective of gender, PEW vs. non-PEW patients had smaller RF, VI muscles, and RF (all < 0.001). US muscle sites (all < 0.001) discriminated PEW from non-PEW patients, but the RF compared to bio-impedance spectroscopy had a greater area under the curve (AUC, 0.686 vs. 0.581), sensitivity (72.8% vs. 65.8%), and specificity (55.6% vs. 53.9%). AUC of the RF was greatest for PEW risk in men (0.74, 95% CI: 0.66-0.82) and women (0.80, 95% CI: 0.70-0.90) (both < 0.001). Gender-specific RF values (men < 6.00 cm; women < 4.47 cm) indicated HD patients with smaller RF were 8 times more likely to have PEW (AOR = 8.63, 95% CI: 4.80-15.50, < 0.001). The US approach enabled discrimination of muscle wasting in HD patients with PEW. The RF was identified as the best US site with gender-specific RF values to associate with PEW risk, suggesting potential diagnostic criteria for muscle wasting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700501PMC
http://dx.doi.org/10.3390/nu12113597DOI Listing

Publication Analysis

Top Keywords

muscle wasting
12
pew
9
quadriceps muscle
8
protein energy
8
energy wasting
8
hemodialysis patients
8
pew identified
8
pew non-pew
8
non-pew patients
8
patients smaller
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!