A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of the diagnostic value of virtual touch tissue quantification and virtual touch tissue imaging quantification in infants with biliary atresia. | LitMetric

Objective: This study aimed to compare the diagnostic performance of vital touch tissue quantification (VTQ) and virtual touch tissue imaging quantification (VTIQ) in diagnosing infants with biliary atresia (BA) from jaundiced infants.

Methods: In this study, 26 jaundiced infants with BA, 33 jaundiced infants without BA, and 40 normal infants were enrolled. The hepatic shear wave velocity (SWV) of each infant was determined by VTQ and VTIQ examinations, respectively. Then, the receiver operating characteristic (ROC) curves were drawn and the area under the curve (AUC) and optimal cut-off values were calculated to evaluate the sensitivities and specificities of VTIQ and VTQ for BA.

Results: The mean values of SWV of the control group measured by VTQ and VTIQ were (1.09 ± 0.18) m/s and (1.36 ± 0.21) m/s, respectively. The mean values of SWV of the non-BA group measured by VTQ and VTIQ were (1.30 ± 0.28) m/s and (1.52 ± 0.29) m/s, respectively. The mean values of SWV of the BA group measured by VTQ and VTIQ were (2.36 ± 0.36) m/s and (2.43 ± 0.29) m/s, respectively. The diagnostic threshold of VTQ and VTIQ to diagnose BA was 1.77 and 1.92 m/s. The sensitivities of VTQ and VTIQ to diagnose BA were 90.9% and 95.5%. The specificities of VTQ and VTIQ to diagnose BA were 68.4% and 78.9%.

Conclusion: Vital touch tissue quantification and VTIQ could help distinguish infants with BA from jaundiced infants by measuring the liver SWV values. VTIQ has higher sensitivity and specificity than VTQ.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ijcp.13860DOI Listing

Publication Analysis

Top Keywords

vtq vtiq
28
touch tissue
20
virtual touch
12
tissue quantification
12
jaundiced infants
12
values swv
12
group measured
12
measured vtq
12
vtiq diagnose
12
vtiq
11

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!