Power Control during Remote Laser Welding Using a Convolutional Neural Network.

Sensors (Basel)

Laboratory for Laser Techniques, Faculty of Mechanical Engineering, University of Ljubljana, Aškerčeva cesta 6, 1000 Ljubljana, Slovenia.

Published: November 2020

The increase in complex workpieces with changing geometries demands advanced control algorithms in order to achieve stable welding regimes. Usually, many experiments are required to identify and confirm the correct welding parameters. We present a method for controlling laser power in a remote laser welding system with a convolutional neural network (CNN) via a PID controller, based on optical triangulation feedback. AISI 304 metal sheets with a cumulative thickness of 1.5 mm were used. A total accuracy of 94% was achieved for CNN models on the test datasets. The rise time of the controller to achieve full penetration was less than 1.0 s from the start of welding. The Gradient-weighted Class Activation Mapping (Grad-CAM) method was used to further understand the decision making of the model. It was determined that the CNN focuses mainly on the area of the interaction zone and can act accordingly if this interaction zone changes in size. Based on additional testing, we proposed improvements to increase overall controller performance and response time by implementing a feed-forward approach at the beginning of welding.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7699901PMC
http://dx.doi.org/10.3390/s20226658DOI Listing

Publication Analysis

Top Keywords

remote laser
8
laser welding
8
convolutional neural
8
neural network
8
interaction zone
8
welding
6
power control
4
control remote
4
welding convolutional
4
network increase
4

Similar Publications

A novel remote deep ultraviolet laser ablation inlet connected to a dual electrospray ionization-atmospheric pressure chemical ionization (rDUVLAESCI) source is presented. This system allows for the simultaneous and spatial acquisition of mass spectrometry (MS) data for organic molecules with diverse polarities and molecular weights. Deep 193 nm UV laser ablation was used to sample analytes from dried spots for molecular MS analysis precisely.

View Article and Find Full Text PDF

Purpose: To report a case of herpes simplex virus (HSV) endotheliitis inducing acute interface fluid syndrome in a patient with a remote history of laser in situ keratomileusis (LASIK).

Methods: Case report and literature review.

Results: A 51-year-old man with a history of LASIK 16 years prior presented with unilateral HSV endotheliitis and was found to have acute interface fluid syndrome secondary to endothelial decompensation.

View Article and Find Full Text PDF

A review of uranium (U) elemental detection methods.

Anal Methods

January 2025

National Key Laboratory of Uranium Resources Exploration-Mining and Nuclear Remote Sensing, Beijing, 100029, China.

With the increasing demand for energy, nuclear energy has been developing rapidly. The quantitative detection and qualitative identification of uranium (U) are of great significance for the comprehensive and efficient use of U resources and the control of nuclear and radioactive substances. In this study, the detection of U is divided into liquid sample detection, solid sample detection, gas sample detection, and industrial detection from the perspectives of the sample state and detection environment.

View Article and Find Full Text PDF

Teleguided photocoagulation treatments across continents with a remotely programmed laser for retinal diseases.

Ther Adv Ophthalmol

January 2025

Department of Experimental Medicine, Ophthalmology Unit, University of Rome Tor Vergata, Via Montpellier 1, Rome, 00133, Italy.

Diabetic retinopathy and retinal vein occlusion represent two prevalent vision-threatening retinal diseases. Retinal laser therapy still plays an important role in treating these conditions, but its successful administration often requires referral to specialized centers and retina experts. It is, therefore, essential to develop a new treatment methodology that enables patients to benefit from the expertise of specialists from reference centers.

View Article and Find Full Text PDF

Purpose: To compare the outcomes of two different surgical planning strategies for topography-guided repair of post-LASIK ectasia.

Methods: This is a case report of a patient presenting with post-LASIK ectasia. A retrospective chart review was used to collect details of the ophthalmic exam, as well as ocular imaging such as anterior segment optical coherence tomography and Scheimpflug corneal tomography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!