Characterization of Nano-Gravimetric-Detector Response and Application to Petroleum Fluids up to C.

Anal Chem

Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, F-69100 Villeurbanne, France.

Published: December 2020

A nano-gravimetric detector (NGD) for gas chromatography is based on a nanoelectromechanical array of adsorbent-coated resonating double clamped beams. NGD is a concentration-sensitive detector and its sensitivity is analyte-dependent based on the affinity of the analyte with the porous layer coated on the NEMS surface. This affinity is also strongly related to the NGD temperature (NGD working temperature can be dynamically set up from 40 to 220 °C), so the sensitivity can be tuned through temperature detector control. An adsorption-desorption model was set up to characterize the NGD response on a large set of -alkanes from C to C at different NGD temperatures. For fast identification of petroleum mixture based on chromatogram fingerprint, a general strategy for NGD temperature program design was developed leading to a constant relative response factor between 0.96 and 1.03 for all the alkanes, and then chromatograms are very similar to those obtained with a flame ionization detector (FID). The analysis of a real petroleum fluid was also performed and compared to FID results: quantitative results obtained for all the analytes were satisfactory according to precision (<5%) and accuracy (average relative error = 4.3%). Based on such temperature control strategy, NGD sensitivity and the dynamic linear range can be adjusted and detection limits at a picogram level can be easily achieved for all -alkanes.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.0c03157DOI Listing

Publication Analysis

Top Keywords

ngd temperature
8
ngd
7
characterization nano-gravimetric-detector
4
nano-gravimetric-detector response
4
response application
4
application petroleum
4
petroleum fluids
4
fluids nano-gravimetric
4
detector
4
nano-gravimetric detector
4

Similar Publications

Nano-gravimetric detector (NGD) has been recently introduced as miniaturized gas chromatography detector. The NGD response is based on an adsorption-desorption mechanism of compounds between the gaseous phase and the NGD porous oxide layer. The NGD response was characterized by hyphenating NGD in-line with FID detector and a chromatographic column.

View Article and Find Full Text PDF

Effect of Different Temperatures on the Hydration Kinetics of Urea-Doped Cement Pastes.

Materials (Basel)

November 2022

School of Water Conservancy and Hydroelectric Power, Hebei University of Engineering, Handan 056038, China.

Urea can solve the problem of concrete cracking due to temperature stress. However, its effect is affected by temperature. The influencing mechanism of temperature on urea-doped cement pastes is still unclear.

View Article and Find Full Text PDF

Electrochemical Sensor Made with 3D Micro-/Mesoporous Structures of CoNi-N/GaN for Noninvasive Detection of Glucose.

ACS Appl Mater Interfaces

November 2022

Key Laboratory of Integrated Circuit and Biomedical Electronic System, School of Artificial Intelligence, Faculty of Electronic Information and Electrical Engineering, Dalian University of Technology, Dalian116024, Liaoning, China.

Noninvasive detection of glucose (NGD) is important because ∼10% of the global population is suffering from diabetes. Herein, a three-dimensional (3D) micro-/mesoporous structure, i.e.

View Article and Find Full Text PDF

The decoction turns into a complex multiphase system following exposure to high temperature and a complex chemical environment. However, the differences in the concentration of key active ingredients in different phase states and the release of drugs in sedimentary phase have yet to be elucidated. A simple ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous quantitative determination of brucine, strychnine, liquiritin, isoliquiritin, isoliquiritigenin and glycyrrhizic acid concentrations and it was applied to compare the content of different phases and measure the release characteristics of the sedimentary phase in "-" decoction (NGD).

View Article and Find Full Text PDF

Characterization of Nano-Gravimetric-Detector Response and Application to Petroleum Fluids up to C.

Anal Chem

December 2020

Université de Lyon, CNRS, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR 5280, 5 rue de la Doua, F-69100 Villeurbanne, France.

A nano-gravimetric detector (NGD) for gas chromatography is based on a nanoelectromechanical array of adsorbent-coated resonating double clamped beams. NGD is a concentration-sensitive detector and its sensitivity is analyte-dependent based on the affinity of the analyte with the porous layer coated on the NEMS surface. This affinity is also strongly related to the NGD temperature (NGD working temperature can be dynamically set up from 40 to 220 °C), so the sensitivity can be tuned through temperature detector control.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!