A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

GORE-TEX SCLERAL-SUTURED ENVISTA INTRAOCULAR LENS DISLOCATION: THREE CASES AND AN ASSESSMENT OF EYELET TENSILE STRENGTH, FRACTURE CHARACTERISTICS, AND RISK FACTORS. | LitMetric

Purpose: Three cases of dislocation of a Gore-Tex scleral-sutured EnVista intraocular lens are reported. The tensile strength of the lens eyelets under two suturing methods is assessed. Pursuant surgical considerations are discussed.

Methods: A chart review was performed to identify cases of scleral-sutured EnVista lens dislocations. In addition, six EnVista lenses were suspended in a balanced salt solution tank, tied either with suture over haptic or simple pass technique. Eyelet tensile strength was calculated by gradual addition of weights. Eyelet fracture position and width were measured. The tensile strength of one additional EnVista lens was assessed in open air.

Patients: In a retrospective, consecutive case series, three dislocated lenses were identified out of 17 surgeries from one institution. Two dislocations occurred postoperatively, and one occurred intraoperatively.

Results: The EnVista eyelet demonstrated greater tensile strength tied with the simple pass method (0.27 ± 0.017 N, n = 3) than with the suture over haptic method (0.15 ± 0.016 N, n = 3; P = 0.0015). Eyelet fracture location corresponded to tensile strength. The lens in air withstood greater tensile stress.

Conclusion: Stress is placed on different regions of the eyelet with each suturing method. Simple pass may withstand greater tension and decrease risk for lens fracture, but the operating surgeon must consider multiple factors when forming an operative plan.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICB.0000000000001099DOI Listing

Publication Analysis

Top Keywords

tensile strength
24
scleral-sutured envista
12
simple pass
12
gore-tex scleral-sutured
8
envista intraocular
8
intraocular lens
8
three cases
8
eyelet tensile
8
strength lens
8
envista lens
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!