Background: The objective of the current study was to summarize and evaluate all published evidence regarding viscoelastic testing in the field of liver surgery.

Methods: A systematic search of the literature was performed using Medline/PubMed, Scopus, Cochrane Library Central, Google Scholar, and clinicaltrials.gov databases. The following keywords were used:"Thromboelastography", "Thromboelastometry", "Viscoelastic tests OR testing", "Sonoclot Devices", "Point-of-care tests OR testing", "Coagulation OR Haemostasis OR Hemostasis", "Liver OR Hepatic Surgery", "Cirrhosis."

Results: A total of 12 studies analyzing 348 patients who underwent viscoelastic testing of coagulation during liver surgery for benign or malignant diseases were included; 7 (58.3%) studies reported on the use of thromboelastography (TEG), and 5 (41.7%) reported on rotational thromboelastometry (ROTEM). Viscoelastic testing (TEG and ROTEM) identified normo-, hyper- and hypo-coagulable status in 77% (n = 268/348), 18.4% (n = 64/348), and 4.6% (n = 16/348) of patients, respectively. In contrast, conventional coagulation tests indicated normo-coagulability in 111 patients (34.2% out of 325) and hypo-coagulability in 214 (65.8% out of 325) patients following liver resection. No patient (0% out of 291) experienced postoperative hemorrhage, whereas 5.8% (n = 17/291) experienced postoperative thromboembolic events.

Conclusions: Global viscoelastic testing may be a reasonable adjunct to conventional coagulation testing to provide a more robust assessment of the coagulation status of patients undergoing liver surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hpb.2020.10.023DOI Listing

Publication Analysis

Top Keywords

viscoelastic testing
16
liver surgery
12
coagulation testing
8
tests testing"
8
conventional coagulation
8
experienced postoperative
8
testing
6
coagulation
5
liver
5
patients
5

Similar Publications

Mechanical characteristics of spinal cord tissue by indentation.

J Mech Behav Biomed Mater

December 2024

Institute of Continuum Mechanics and Biomechanics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Dr.-Mack-Straße 81, Fürth, 90762, Germany. Electronic address:

The mechanical properties of brain and spinal cord tissue have proven to be extremely complex and difficult to assess. Due to the heterogeneous and ultra-soft nature of the tissue, the available literature shows a large variance in mechanical parameters derived from experiments. In this study, we performed a series of indentation experiments to systematically investigate the mechanical properties of porcine spinal cord tissue in terms of their sensitivity to indentation tip diameter, loading rate, holding time, ambient temperature along with cyclic and oscillatory dynamic loading.

View Article and Find Full Text PDF

Accurate replication of soft tissue properties is essential for the development of car crash test dummy skin to ensure the precision of biomechanical injury data. However, the intricacy of multi-layer soft tissue poses challenges in standardizing the development and testing of dummy skin materials to emulate soft tissue properties. This study presents a comprehensive testing and analysis of the compressive mechanical properties of both single and multi-layered soft tissues and car crash dummy skin materials, aiming to enhance the biofidelity of dummy skin.

View Article and Find Full Text PDF

Rheological Properties and Physical Stability of Aqueous Dispersions of Flaxseed Fibers.

Gels

December 2024

Departamento de Ingeniería Química, Escuela Politécnica Superior, Universidad de Sevilla, E41011 Sevilla, Spain.

The main objective of this work is to investigate the influence of shear on the rheological properties and physical stability of aqueous dispersions of flaxseed fiber. The variable to consider will be the homogenization rate in two different rotor-stator homogenizers, Ultraturrax T50 or T25. In order to achieve the proposed objective, small amplitude oscillatory tests, flow curves, and multiple light scattering measurements were carried out.

View Article and Find Full Text PDF

This study presents the development of thiol-maleimide/thiol-thiol double self-crosslinking hyaluronic acid-based (HA) hydrogels for use as dermal fillers. Hyaluronic acid with varying degrees of maleimide substitution (10%, 20%, and 30%) was synthesized and characterized, and HA hydrogels were fabricated using two molecular weights of four-arm polyethylene glycol (PEG10K/20K)-thiol as crosslinkers. The six resulting HA hydrogels demonstrated solid-like behavior with distinct physical and rheological properties.

View Article and Find Full Text PDF

Active and passive material response of urinary bladder smooth muscle tissue in uniaxial and biaxial tensile testing.

Acta Biomater

December 2024

Department of Sport and Motion Science, University of Stuttgart, Stuttgart, Germany; Stuttgart Center for Simulation Science, University of Stuttgart, Stuttgart, Germany.

The urinary bladder is a hollow organ that undergoes significant deformation as it receives, stores, and releases urine. To understand the organ mechanics, it is necessary to obtain information about the material properties of the tissues involved. In displacement-controlled tensile tests, tissue samples are mounted on a device that applies stretches to the tissue in one or more directions, resulting in a specific stress response.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!