A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel Approach for the Accurate Determination of Se Isotope Ratio by Multicollector ICP-MS. | LitMetric

Novel Approach for the Accurate Determination of Se Isotope Ratio by Multicollector ICP-MS.

Anal Chem

Faculty of Chemistry, Biological and Chemical Research Centre, University of Warsaw, Zwirki i Wigury 101, 02-093 Warsaw, Poland.

Published: December 2020

In this work, a method for the accurate and precise determination of Se/Se isotope ratio in natural samples of environmental and biological origin, using multicollector inductively coupled plasma mass spectrometry in a wet plasma mode without using neither hydride generation nor separation of Se, was developed. It was based on the optimized regression model with standard-sample bracketing (ORM-SSB) to efficiently correct instrumental isotopic fractionation/mass bias and matrix effects. In addition, three mass bias correction models of SSB alone, SSB combined with internal standard (IS-SSB), and ORM-SSB were compared for the Se isotope ratio measurements. NIST SRM 987 Sr was used as an internal standard, and the reproducibility of the results obtained with the proposed method was verified by measuring NIST SRM 3149 standard over different days (nine independent measurement sessions). Delta values of the Se/Se isotope ratio were measured in selenium-enriched yeast-certified reference material SELM-1, natural selenomethionine samples, and model solutions of artificial seawater. Solutions obtained after thiol resin treatment were measured to demonstrate the applicability of the proposed method in eliminating matrix effects due to residual of thiol resin in the sample solutions. Among three mass bias correction models, ORM-SSB correction model proved to be the best to eliminate the matrix effects and instrumental drift. IS-SSB model offered also a good precision but was slightly less accurate. Both models showed good robustness against effects of different sample matrices. Finally, the SSB alone could not be recommended for Se isotope analysis as it produces inaccurate and imprecise results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7745200PMC
http://dx.doi.org/10.1021/acs.analchem.0c03768DOI Listing

Publication Analysis

Top Keywords

isotope ratio
16
matrix effects
12
se/se isotope
8
three mass
8
mass bias
8
bias correction
8
correction models
8
internal standard
8
nist srm
8
proposed method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!