A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Potentialities and limitations of computer-aided design and manufacturing technology in the nonextraction treatment of Class I malocclusion. | LitMetric

Introduction: Computer-aided design and manufacturing (CAD-CAM) systems have assisted orthodontists to position brackets virtually. The purpose of this study was to evaluate if a CAD-CAM system could predict the orthodontic treatment outcome of patients with Angle Class I malocclusion with mild crowding or spacing and with no need for orthodontic extraction.

Methods: Using the American Board of Orthodontics Cast-Radiograph Evaluation (ABO-CRE) and color map superimposition, the treated occlusion was compared with the virtual final occlusion of 24 young adults with Class I occlusion. Using eXceed software (eXceed, Witten, Germany), we created the final occlusion prediction for each patient (virtual set up group). A digital model of the final occlusion of each patient was created (treated occlusion group). ABO-CRE score was used to compare groups. In addition, a color map was created for all subjects to access the mean and range values between the virtual set up model and treated occlusion model of each patient. Random and systematic errors were calculated. In addition, chi-square and t test were used.

Results: Comparisons between virtual set up occlusion and treated occlusion showed statistically significant differences in 3 out of 7 measurements: interproximal contact score was larger for treated than virtual occlusion (0.45 mm and 0.04 mm, respectively), and the treated occlusion showed larger values than the virtual occlusion for occlusal contacts (14.13 mm and 7.62 mm, respectively) and overjet (7.37 mm and 0.66 mm, respectively). Although the treated occlusion showed a larger score than the virtual occlusion (50.41 mm and 34.58 mm, respectively), there is no significant difference between both. Root angulation decreased (from 1.95 ± 1.29 to 0.65 ± 0.71) because of the treatment.

Conclusions: ABO-CRE overall score presents no difference between groups. In addition, CAD-CAM setup occlusion closely predicts the final teeth alignment and leveling with interarch relationships showing less ABO-CRE score deduction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajodo.2020.04.020DOI Listing

Publication Analysis

Top Keywords

treated occlusion
24
occlusion
15
final occlusion
12
virtual set
12
abo-cre score
12
virtual occlusion
12
computer-aided design
8
design manufacturing
8
class malocclusion
8
color map
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!