Altered stress field of the human lens capsule after cataract surgery.

J Biomech

Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, United States. Electronic address:

Published: January 2021

The lens capsule of the eye is important in focusing light onto the retina during the process of accommodation and, in later life, housing a prosthetic lens implanted during cataract surgery. Though considerable modeling work has characterized the mechanics of accommodation, little has been done to understand the mechanics of the lens capsule after cataract surgery. As such, we present the first 3-D finite element model of the post-surgical human lens capsule with an implanted tension ring and, separately, an intraocular lens to characterize the altered stress field compared to that in a model of the native lens capsule. All finite element models employed a Holzapfel hyperelastic constitutive model with regional variations in anisotropy. The post-surgical lens capsule demonstrated a dramatic perturbation to the stress field with mostly large reductions in stresses (except at the equator where the implant contacts the capsule) compared to native, wherein maximal changes in Cauchy stress were -100% and -145% for the tension ring and intraocular lens, respectively. However, implantation of the tension ring produced a more uniform stress field compared to the IOL. The magnitudes and distribution of the perturbed stress field may be an important driver of the fibrotic response of inhabiting lens epithelial cells and associated lens capsule remodeling after cataract surgery. Thus, the mechanical effects of an implant on the lens capsule could be an essential consideration in the design of intraocular lenses, particularly those with an accommodative feature.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7856179PMC
http://dx.doi.org/10.1016/j.jbiomech.2020.110127DOI Listing

Publication Analysis

Top Keywords

lens capsule
32
stress field
20
cataract surgery
16
lens
12
tension ring
12
capsule
9
altered stress
8
human lens
8
capsule cataract
8
finite element
8

Similar Publications

Pseudoexfoliation syndrome (PXS) is an age-related fibrillopathy where fibrillar exfoliation material accumulates and deposits in ocular and extra-ocular tissue. Within the eye, this substance accumulates on the ocular surface and in the anterior segment of the eye, impacting ocular structures such as the conjunctiva, Tenon's capsule, sclera, cornea, iris, ciliary body, trabecular meshwork, and lens. This review aims to collate the current literature on how each anatomical part of the eye is affected by PXS, with a strong focus on molecular changes.

View Article and Find Full Text PDF

We describe a novel experimental device, the VaMa (Vatavuk and Marić) artificial intraocular lens (IOL) capsule, and a method that enables all IOL types to be implanted in the bag. We present the application of the device and the procedure in patients with aphakia and native capsule damage and without efficient capsular support. The VaMa device and the method facilitate IOL exchange due to refractive errors and, in the case of their invention, the implementation of superior IOLs in the future.

View Article and Find Full Text PDF

Purpose: Proliferative vitreoretinopathy (PVR) is a complication of retinal detachment which requires multiple vitreoretinal surgical interventions and frequent use of oil endotamponade. In this study, we conducted an in-depth analysis of complications associated with the use of heavy silicone oil in the management of inferior PVR.

Methods: A retrospective cohort study of 20 eyes that underwent vitrectomy for inferior PVR with use of heavy silicone oil (Densiron 68) between March 2021 and October 2022 at Oxford Eye Hospital.

View Article and Find Full Text PDF

Background: Human anterior lens capsules (ALCs) have great potential in the treatment of multiple eye diseases, including corneal ulcers, glaucoma, age-related macular degeneration and macular holes. ALCs are also regarded as promising scaffolds for various ocular cells. Here, we investigated different decellularization methods for removing lens epithelial cells (LECs) that adhered to ALCs.

View Article and Find Full Text PDF

Rationale: The double-layer sign of the anterior lens capsule during continuous curvilinear capsulorrhexis (CCC) in cataract surgery is a rare phenomenon. This case report highlights the occurrence of this sign and provides a practical technique for managing it.

Patient Concerns: A 55-year-old Chinese woman presented with blurred vision in her left eye.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!