Objectives: Our goal was to compare results between a standard computed tomography (CT)-based strategy, the 'three-step preoperative sequential planning' (3-step PSP), for pulmonary valve replacement in repaired tetralogy of Fallot versus a conventional planning approach.

Methods: We carried out a retrospective study with unmatched and matched groups. The 3-step PSP comprised the planning of mediastinal re-entry, cannulation for cardiopulmonary bypass (CPB) and the main procedure, using standard 3-dimensional videos. Operative times (skin incision to CPB, CPB time, end of CPB to skin closure and cross-clamp time) as well as postoperative length of stay and in-hospital mortality were compared.

Results: Eighty-two patients (49% classical tetralogy of Fallot) underwent an operation (85% with pulmonary homograft) with 1.22% in-hospital mortality. The 3-step PSP (n = 14) and the conventional planning (n = 68) groups were compared. There were no statistically significant differences in the preoperative characteristics. Differences were observed in the total operative time (P = 0.009), skin incision to CPB (P = 0.034) and cross-clamp times (74 ± 33 vs 108 ± 47 min; P = 0.006), favouring the 3-step PSP group. Eight matched pairs were compared showing differences in the total operative time (263 ± 44 vs 360 ± 66 min; P = 0.008), CPB time (123 ± 34 vs 190 ± 43 min; P = 0.008) and postoperative length of stay (P = 0.031), favouring the 3-step PSP group.

Conclusions: In patients with repaired tetralogy of Fallot undergoing pulmonary valve replacement, preoperative planning using a standard CT-based strategy, the 3-step PSP, is associated with shorter operative times and shorter postoperative length of stay.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7954262PMC
http://dx.doi.org/10.1093/ejcts/ezaa346DOI Listing

Publication Analysis

Top Keywords

3-step psp
24
tetralogy fallot
16
pulmonary valve
12
valve replacement
12
repaired tetralogy
12
postoperative length
12
length stay
12
preoperative sequential
8
replacement repaired
8
computed tomography
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!