Purpose: The pulsed-electron avalanche knife (PEAK) PlasmaBlade TnA (Medtronic, n.d.) is a relatively new electrosurgical technology that is used widely in head and neck surgery (Medtronic Manuals, n.d.). This study aims to summarize device malfunctions, patient complications, and subsequent interventions related to PEAK PlasmaBlade TnA during tonsillectomy and adenoidectomy.
Materials And Methods: The US Food and Drug Administration's Manufacture and User Facility Device Experience database was queried for reports of PlasmaBlade TnA adverse events from June 6, 2009, to August 30, 2020. Data were extracted from reports pertaining to tonsillectomy with or without adenoidectomy.
Results: 128 reports were identified, from which 163 adverse events were extracted. Of these, 23 (14.6%) were related to patients, and 140 (85.4%) were related to device malfunction. The most frequently reported patient-related adverse event was a burn injury (17 [73.9%]). The most common device malfunctions were dislodgment of device component (39 [27.9%]), followed by tip ignition (32 [22.9%]), damaged tip or wire during operation (28 [20%]), and melted device (24 [17.1%]).
Conclusions: PEAK PlasmaBlade TnA have demonstrated utility in tonsillectomy with or without adenoidectomy but are associated with adverse events. Interventions aimed at improving both physician and patient education may help reduce adverse events attributed to improper use. Further study is needed to clarify optimal approaches to education.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjoto.2020.102826 | DOI Listing |
Auris Nasus Larynx
February 2022
Department of Otolaryngology-Head and Neck Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, 5, Fu-shin street, Kweishan 333, Taoyuan, Taiwan; School of Medicine, Chang Gung University, Taoyuan, Taiwan.
Objective: Tracheal granulation is one of the common long term complications in patients after tracheostomy. Hypertrophic tracheal granulation may cause airway obstruction and further operation may be required to recreate an airway. Distal tracheal granulation is clinically challenging because of its position and surgical field limitation.
View Article and Find Full Text PDFAm J Otolaryngol
April 2021
Division of Otolaryngology-Head and Neck Surgery, George Washington University School of Medicine & Health Sciences, Washington, DC, United States of America. Electronic address:
Purpose: The pulsed-electron avalanche knife (PEAK) PlasmaBlade TnA (Medtronic, n.d.) is a relatively new electrosurgical technology that is used widely in head and neck surgery (Medtronic Manuals, n.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!