A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Increasing SARS-CoV-2 RT-qPCR testing capacity by sample pooling. | LitMetric

Increasing SARS-CoV-2 RT-qPCR testing capacity by sample pooling.

Int J Infect Dis

Genomics Division, Instituto Tecnológico y de Energías Renovables, Santa Cruz de Tenerife, Spain; Research Unit, Hospital Universitario N. S. de Candelaria, Santa Cruz de Tenerife, Spain; CIBER de Enfermedades Respiratorias, Instituto de Salud Carlos III, Madrid, Spain; Instituto de Tecnologías Biomédicas, Universidad de La Laguna, San Cristóbal de la Laguna, Spain. Electronic address:

Published: February 2021

Objectives: Limited testing capacity has characterized the ongoing coronavirus disease 2019 (COVID-19) pandemic in Spain, hampering timely control of outbreaks and opportunities to reduce the escalation of community transmission. This study investigated the potential to use sample pooling, followed by one-step retrotranscription and real-time quantitative reverse transcription polymerase chain reaction (RT-qPCR) to increase testing capacity for severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2).

Methods: Various pool sizes (five, 10 and 15 samples) were evaluated prior to RNA extraction followed by standard RT-qPCR for the diagnosis of COVID-19. The pool size achieving reproducible results with individual sample testing was subsequently used to assess nasopharyngeal samples in a tertiary hospital in August 2020.

Results: A pool size of five samples had higher sensitivity compared with pool sizes of 10 and 15 samples, showing a mean cycle threshold (Ct) shift of 3.5 [standard deviation (SD) 2.2] between the pooled test and positive samples in the pool. Next, a pool size of five was used to test a total of 895 pools (4475 prospective samples) using two different RT-qPCR kits. The Real Accurate Quadruplex corona-plus PCR Kit (PathoFinder) reported the lowest mean Ct shift [2.2 (SD 2.4)] between the pool and individual samples. This strategy enables detection of individual positive samples in positive pools with Ct of 16.7-39.4.

Conclusions: Grouping samples into pools of five for RT-qPCR resulted in an increase in SARS-CoV-2 testing capacity with minimal loss of sensitivity compared with testing each sample individually.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7674967PMC
http://dx.doi.org/10.1016/j.ijid.2020.11.155DOI Listing

Publication Analysis

Top Keywords

testing capacity
16
pool size
12
samples
9
sample pooling
8
rt-qpcr increase
8
pool sizes
8
sizes samples
8
sensitivity compared
8
positive samples
8
pool
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!