Sensor Architectures and Technologies for Upper Limb 3D Surface Reconstruction: A Review.

Sensors (Basel)

Department of Civil and Industrial Engineering, University of Pisa, Largo L. Lazzarino, 1, 56122 Pisa, Italy.

Published: November 2020

3D digital models of the upper limb anatomy represent the starting point for the design process of bespoke devices, such as orthoses and prostheses, which can be modeled on the actual patient's anatomy by using CAD (Computer Aided Design) tools. The ongoing research on optical scanning methodologies has allowed the development of technologies that allow the surface reconstruction of the upper limb anatomy through procedures characterized by minimum discomfort for the patient. However, the 3D optical scanning of upper limbs is a complex task that requires solving problematic aspects, such as the difficulty of keeping the hand in a stable position and the presence of artefacts due to involuntary movements. Scientific literature, indeed, investigated different approaches in this regard by either integrating commercial devices, to create customized sensor architectures, or by developing innovative 3D acquisition techniques. The present work is aimed at presenting an overview of the state of the art of optical technologies and sensor architectures for the surface acquisition of upper limb anatomies. The review analyzes the working principles at the basis of existing devices and proposes a categorization of the approaches based on handling, pre/post-processing effort, and potentialities in real-time scanning. An in-depth analysis of strengths and weaknesses of the approaches proposed by the research community is also provided to give valuable support in selecting the most appropriate solution for the specific application to be addressed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7698754PMC
http://dx.doi.org/10.3390/s20226584DOI Listing

Publication Analysis

Top Keywords

upper limb
16
sensor architectures
12
surface reconstruction
8
limb anatomy
8
optical scanning
8
upper
5
architectures technologies
4
technologies upper
4
limb
4
limb surface
4

Similar Publications

When we touch ourselves, the pressure appears weaker compared to when someone else touches us, an effect known as sensory attenuation. Sensory attenuation is spatially tuned and does only occur if the positions of the touching and the touched body-party spatially coincide. Here, we ask about the contribution of visual or proprioceptive signals to determine self-touch.

View Article and Find Full Text PDF

Safety of accessing brachial veins for large-bore upper extremity venous thrombectomy using ClotTriever Thrombectomy System.

CVIR Endovasc

January 2025

Department of Radiology, Section of Vascular and Interventional Radiology, University of Washington, 1959 Northeast Pacific Street, Seattle, WA, 98195, USA.

Purpose: To evaluate access site adverse events following ClotTriever-mediated large-bore mechanical thrombectomy via small upper extremity deep veins (< 6-mm).

Materials And Methods: Twenty patients, including 24 upper extremity venous access sites, underwent ClotTriever-mediated large-bore thrombectomy of the upper extremity and thoracic central veins for symptomatic deep vein obstruction unresponsive to anticoagulation. Patients without follow-up venous duplex examinations (n = 3) were excluded.

View Article and Find Full Text PDF

Background: Although both the lateral sagittal and costoclavicular approaches are applied at the cord level in the infraclavicular region, there is a major difference between the distributions of the two approaches. We aimed to investigate the effects of this different distribution on tissue perfusion and oxygenation.

Methods: Sixty patients undergoing elective elbow, forearm, wrist and hand surgery under infraclavicular brachial plexus block were included in the study.

View Article and Find Full Text PDF

Purpose: Our goal was to determine the association between the severity of electrodiagnostic (EDX) studies with the cross-sectional area (CSA) of the ulnar nerve at the cubital tunnel using diagnostic ultrasound. Based on our clinical experience, we hypothesized there would not be a positive correlation between the severity of EDX and ulnar nerve CSA.

Methods: This was a retrospective analysis of patients 18 years or older evaluated from May 1, 2020, to June 31, 2021, referred for an upper limb EDX and neuromuscular ultrasound to evaluate for an upper limb neuropathy.

View Article and Find Full Text PDF

Objective: Limited information is available regarding the associations between upper extremity function, activities of daily living (ADLs), and functional capacity in patients with heart failure with reduced ejection fraction (HFrEF). This study aimed to investigate the associations between upper extremity function, ADLs, and functional capacity in patients with HFrEF.

Methods: This cross-sectional study included 31 patients with HFrEF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!