Objectives: This study sought to compare patient characteristics, procedural outcomes, and valve hemodynamics of surgical aortic valve replacement (SAVR) with current-generation rapid-deployment valves (RDVs) versus transcatheter aortic valve replacement (TAVR) with current-generation transcatheter heart valves (THVs).

Background: The patient population currently treated with RDVs may have potential similarities with the current TAVR population, but comparative studies in a large patient population remain scarce.

Methods: A total of 16,473 patients who underwent isolated SAVR using current-generation RDVs or isolated transfemoral TAVR with current-generation THVs between 2011 and 2017 were enrolled into the German Aortic Valve Registry. Baseline, procedural, and in-hospital outcome parameters were analyzed for RDVs and THVs before and after 1:1 propensity score matching. Furthermore, RDVs and THVs with similar design characteristics were compared with each other.

Results: A total of 1,743 patients received SAVR with an RDV, whereas 14,730 patients were treated with transfemoral TAVR. Patients treated with TAVR were significantly older and had higher surgical risk scores. Following valve replacement, patients treated with an RDV had a significantly higher rate of disabling stroke (1.7% vs. 1.1%; p = 0.03), need for transfusion of >4 red blood cell units (8.5% vs. 1.4%; p < 0.001), and new onset renal replacement therapy (1.9% vs. 1.2%; p = 0.01), whereas the need for a new permanent pacemaker was lower (8.4% vs. 14.9%; p < 0.001). In-hospital mortality was similar (1.6% vs. 1.8%; p = 0.62). These findings persisted after 1:1 propensity score matching, but in-hospital mortality was significantly higher after RDVs (1.7% vs. 0.6%; p = 0.003). Balloon-expandable (BE) RDVs had significantly lower residual gradients compared with BE-THVs, while self-expanding (SE)-RDVs had significantly higher residual gradients compared with SE-THVs.

Conclusions: In a large all-comers' registry, TAVR with current-generation THVs was associated with improved in-hospital outcomes compared with SAVR with current-generation RDVs. The pacemaker rate is significantly higher with TAVR. Post-procedural hemodynamic function varied between individual RDVs and THVs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2020.09.018DOI Listing

Publication Analysis

Top Keywords

aortic valve
20
valve replacement
16
patients treated
12
german aortic
8
valve registry
8
savr current-generation
8
tavr current-generation
8
patient population
8
transfemoral tavr
8
rdvs thvs
8

Similar Publications

: New-onset postoperative atrial fibrillation (POAF) is the most common complication after cardiac surgery, occurring approximately in one-third of the patients. This study considered all-comer patients who underwent cardiac surgery to build a predictive model for POAF. : A total of 3467 (Center 1) consecutive patients were used as a derivation cohort to build the model.

View Article and Find Full Text PDF

Paravalvular leak (PVL) was initially recognized as one of the most common complications after transcatheter aortic valve implantation (TAVI) and has been linked to adverse clinical outcomes, including mortality. This study aims to assess the long-term clinical effects of PVL in patients undergoing TAVI with the latest generation of transcatheter aortic valves, as part of the national observational prospective multicenter study OBSERVANT II. OBSERVANT II included all consecutive patients with severe aortic stenosis who underwent TAVI across 28 Italian centers from December 2016 to September 2018.

View Article and Find Full Text PDF

Previous studies evaluated the prognostic role of hematological parameters in predicting outcome in patients with infective endocarditis (IE). However, only a few studies evaluated the role of hematological parameters in patients undergoing surgery for IE. The aim of this study was to review our 20-year experience with the treatment of native (NVE) and prosthetic (PVE) valve endocarditis and to evaluate the role of neutrophil-to-lymphocyte ratio (NLR), neutrophil-to-platelet ratio (NPR), platelet-to-lymphocyte ratio (PLR), monocyte-to-lymphocyte ratio (MLR), neutrophil-to monocyte ratio (NMR), and systemic inflammatory index (SII) on early and long-term outcomes of patients undergoing surgery for NVE and PVE.

View Article and Find Full Text PDF

Stuck prosthetic valves, often resulting from pannus formation or thrombus accumulation, represent a critical complication in prosthetic valve management, carrying significant risks for morbidity and mortality. This study aims to identify factors associated with stuck valve development and assess the effectiveness of interventions in restoring normal valve function. A total of 27 patients with stuck valves were analyzed, including mitral, aortic, and tricuspid valve cases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!