Experimental and Numerical Analysis of 60-Year-Old Sluice Gate Affected by Long-Term Operation.

Materials (Basel)

Department of Automation and Human Machine Interactions, Faculty of Mechanical Engineering, Technical University of Košice, 042 00 Košice, Slovakia.

Published: November 2020

Technological units of water reservoirs and power plants include sluice gates which are designed to completely seal the inflow or outflow of water in supply or discharge channels. This article describes the issue of technical assessment of a sluice gate made in the 1950s. Such structures are characterised by states of significant corrosive wear, permanent deformations of contact and sealing surfaces as well as increased levels of residual stresses. In such cases, it is difficult to determine service life using only numerical modelling methods, mainly due to problematic definition of material properties and boundary conditions. Therefore, for safety assessment, it is necessary to verify these facts experimentally. This article presents the procedure for assessing safe operation of the sluice gate on which places with permanent deformation and a broken part of the guide wheel flange were identified. By means of numerical modelling, we identified critical stress values at the locations of reinforcing elements, which were modified, and the stress values were reduced by about 15%. The results of numerical modelling were verified at select locations by experimental measurements during operation using strain gauges. The maximum values of operational normal stresses in the assessed places reached about 27 MPa. Based on the comparison of obtained results and taking into account values of residual stresses reaching up to 190 MPa made by shielded metal arc welding, it can be stated that, for safe operation of the sluice gate, it is necessary to follow the proposed procedure during its lowering and to modify the reinforcing elements structurally.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7698616PMC
http://dx.doi.org/10.3390/ma13225201DOI Listing

Publication Analysis

Top Keywords

sluice gate
16
numerical modelling
12
residual stresses
8
safe operation
8
operation sluice
8
stress values
8
reinforcing elements
8
sluice
5
experimental numerical
4
numerical analysis
4

Similar Publications

Temperature-induced cracks during the construction of large concrete structures, such as water gates and bridges, caused by hydration heat, pose a serious threat to structural safety and reliability. To address this, various countries have developed temperature control standards and guidelines for mass concrete structures, providing design direction and evaluation criteria. China and the United States (U.

View Article and Find Full Text PDF

Research on Automated Modeling Technology of Sluice Gate Project Based on BIM Technology.

Sensors (Basel)

August 2024

College of Water Conservancy and Hydropower Engineering, Hohai University, Nanjing 210098, China.

In order to improve the efficiency and accuracy of the modeling and design work of the sluice gate project, this paper proposes an automatic generation template of the sluice gate project with customized semantics and project layout scheme, aiming at realizing the rapid assembling of all kinds of components of the sluice gate project. In the construction process, this paper first starts from basic parametric modeling and proposes constraints as the basis of modeling. Subsequently, a template library framework is developed based on the constraints to ensure that the generated templates have a high degree of standardization and consistency.

View Article and Find Full Text PDF

Accurate calculation of flow discharge for sluice gates is essential in irrigation, water supply, and structure safety. The measurement of discharge with the requirement of distinguishing flow regimes is not conducive to application. In this study, a novel approach that considers both free and submerged flow was proposed.

View Article and Find Full Text PDF

The customization of hybrid nanofluids to achieve a particular and controlled growth rate of thermal transport is done to meet the needs of applications in heating and cooling systems, aerospace and automotive industries, etc. Due to the extensive applications, the aim of the current paper is to derive a numerical solution to a wall jet flow problem through a stretching surface. To study the flow problem, authors have considered a non-Newtonian Eyring-Powell hybrid nanofluid with water and CoFeOand TiOnanoparticles.

View Article and Find Full Text PDF

Accurate calculation of discharge is a critical task in terms of environmental and operational regulations. In the current study, a new approach for determining vertical sluice gates' flow discharge with a minor bias is proposed. Energy-momentum equations are used to characterize the physical expression of the phenomena intended for generation of the coefficient of discharge.

View Article and Find Full Text PDF