A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spectral Verification of the Mechanisms behind FBG-Based Ultrasonic Guided Wave Detection. | LitMetric

Spectral Verification of the Mechanisms behind FBG-Based Ultrasonic Guided Wave Detection.

Sensors (Basel)

Brussels Photonics (B-PHOT), Department of Applied Physics and Photonics, Vrije Universiteit Brussel and Flanders Make, Pleinlaan 2, B-1050 Brussels, Belgium.

Published: November 2020

Ultrasonic guided wave (UGW) detection with fiber Bragg grating (FBG)-based sensors has received increasing attention in the last decades due to the ability to perform non-destructive inspection (NDI) of large plate-like surfaces with a network of lightweight and multiplexed sensors. For accurate UGW measurements, several studies concluded that the ratio between the wavelength of the UGW and the length of the FBG should be above 7. However, shorter FBGs suffer from a lower FBG reflectivity and less steep slopes in the reflection spectrum. In this work we experimentally verified the effect of a passing UGW on the Bragg peak of FBG sensors of different lengths. By performing edge-filtering interrogation throughout the FBG's reflection spectrum, we were able to reconstruct the FBG's spectral response to a UGW in function of time. Our experimental findings are partially in line with those in the literature considering the UGW wavelength to FBG length ratio and the corresponding Bragg peak changes. We experimentally show for the first time that for shorter FBG sensors, the strain modulation is translated mostly into Bragg peak shifting, while for longer FBG sensors, Bragg peak deformation takes over as main mechanism. Despite the different mechanism for the latter, the UGW can still be detected by edge-filtering on the steepest slope, and with a much higher sensitivity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7698563PMC
http://dx.doi.org/10.3390/s20226571DOI Listing

Publication Analysis

Top Keywords

bragg peak
16
fbg sensors
12
ultrasonic guided
8
guided wave
8
reflection spectrum
8
ugw
7
fbg
6
bragg
5
sensors
5
spectral verification
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!