A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of carcinoembryonic antigen as a tumor marker using a novel graphene-based label-free electrochemical immunosensor. | LitMetric

In this work, a simple label-free electrochemical immunosensor for the detection of carcinoembryonic antigen (CEA) was developed. At first, the GC electrode was coated with partially reduced graphene oxide (rGO) to form a platform to bind the antibody. After activating the carboxyl groups of rGO through the EDC/NHS linker, the electrode surface was covered with the antibody. Then, the electrochemical behavior of the antibody-modified electrode and the parameters of the interactions of antibody-antigen immune complexes were investigated using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). This immune-complex layer was found to attenuate the electrochemical current which can be used as a good signal to determine the antigen concentration. The proposed immunosensor exhibited a good amperometric response to CEA within a concentration range of 0.1-5 ng mL with a detection limit of 0.05 ng ml. Furthermore, the developed method was evaluated for the detection of CEA in the real sample (human blood serum), and the results were comparable with the reference values obtained by the standard enzyme-linked immunosorbent assay (ELISA). Our findings suggest the present immunosensor as a good candidate for application in clinical screening.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ab.2020.114017DOI Listing

Publication Analysis

Top Keywords

carcinoembryonic antigen
8
label-free electrochemical
8
electrochemical immunosensor
8
electrochemical
5
determination carcinoembryonic
4
antigen tumor
4
tumor marker
4
marker novel
4
novel graphene-based
4
graphene-based label-free
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!