Objective: Skin wounds after elliptical removal of benign tumors, are conventially sutured linearly for closure and often result in longer and undesirable scars. We aimed to evaluate the efficiency of four quadrant embedded intradermal purse-string suture closure technique for round defects in order to obtain satisfactory cosmetic outcomes and limited scar.

Materials And Methods: We analysed the features of 143 patients for whom a total of 208 four quadrant embedded purse string sutures were used to completely close their postoperative surgical defects. The location and histopathological types of the tumors removed were noted. Tumors were located in the cervicofacial region, thoracic region, back, lower and upper extremities. The patient and observer scar assessment scale (POSAS) questionairre was utilized to evaluate objective results of the ultimate scar.

Results: The defects of the lesions after excision were closed using intradermal four quadrant buried purse-string suture. The wounds showed good final healing without obvious adverse events postoperatively. Infection occurred only in three patients. The final cosmetic appearance of the healed wounds was satisfying as POSAS scores were 17.74 for patient scar assesment scale (PSAS) and 15.3 for observer scar assessment scale (OSAS).

Conclusion: Four quadrant embedded purse string technique is a simple and useful method to close skin defects after circular resection of lesions. It provides minimal scarring and remarkable patient satisfaction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7651757PMC
http://dx.doi.org/10.5152/eurasianjmed.2020.19203DOI Listing

Publication Analysis

Top Keywords

quadrant embedded
12
purse-string suture
8
embedded purse
8
purse string
8
observer scar
8
scar assessment
8
assessment scale
8
defects
5
quadrant-embedded purse-string
4
purse-string closure
4

Similar Publications

Background: With the advent of monoclonal antibody therapy to treat mild cognitive impairment and mild dementia due to Alzheimer's disease (AD) there is a need to develop tests to screen for neurocognitive difficulty that are reliable and easily deployed.

Method: The Rowan Digital Cancellation Tests (RDCT) is comprised of three tests administered using an iPad Pro. Each test was preceded by a practice trial.

View Article and Find Full Text PDF

Optimized Design of Direct Digital Frequency Synthesizer Based on Hermite Interpolation.

Sensors (Basel)

September 2024

College of Mechanical and Electrical Engineering, Henan University of Science and Technology, Luoyang 471000, China.

To address the issue of suboptimal spectral purity in Direct Digital Frequency Synthesis (DDFS) within resource-constrained environments, this paper proposes an optimized DDFS technique based on cubic Hermite interpolation. Initially, a DDFS hardware architecture is implemented on a Field-Programmable Gate Array (FPGA); subsequently, essential interpolation parameters are extracted by combining the derivative relations of sine and cosine functions with a dual-port Read-Only Memory (ROM) structure using the cubic Hermite interpolation method to reconstruct high-fidelity target waveforms. This approach effectively mitigates spurious issues caused by amplitude quantization during the DDFS digitalization process while reducing data node storage units.

View Article and Find Full Text PDF

Contrary to popular lore, optimal visual acuity is typically better than 20/20. Could correcting acuity beyond 20/20 offer any benefit? An affirmative answer could present new confounds in studies of aging, development, psychiatric illness, neurodegenerative disorders, or any other population where refractive error might be more likely. An affirmative answer would also offer a novel explanation of inter-observer variability in visual performance.

View Article and Find Full Text PDF

A squamous odontogenic tumor (SOT) is an epithelial locally benign neoplasia derived from the periodontium of the jaws. It is considered a lesion of low incidence. Predominantly, it affects the mandible, although both jaw bones may be involved.

View Article and Find Full Text PDF

This work presents a novel multielectrode array (MEA) to quantitatively assess the dose enhancement factor (DEF) produced in a medium by embedded nanoparticles. The MEA has 16 nanocrystalline diamond electrodes (in a cell-culture well), and a single-crystal diamond divided into four quadrants for X-ray dosimetry. DEF was assessed in water solutions with up to a 1000 µg/mL concentration of silver, platinum, and gold nanoparticles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!