The diagnosis of and decision-making for early revision surgery to treat failure of biological fixation with a proximally coated cementless stem are challenging. A 73-year-old woman was referred to our hospital with thigh pain 2 years after the initial total hip arthroplasty. Although a plain radiograph showed no signs indicating biological fixation failure, digital tomosynthesis showed a highly radiodense line along the proximal part, and bone scintigraphy showed uptake at the distal part. With the diagnosis of biological fixation failure due to the proximal-distal mismatch, the cementless stem was revised to a cemented stem, and the thigh pain was improved after the revision surgery. Digital tomosynthesis and bone scintigraphy can be helpful for the diagnosis of biological fixation failure due to proximal-distal mismatch.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7649110PMC
http://dx.doi.org/10.1016/j.artd.2020.09.007DOI Listing

Publication Analysis

Top Keywords

biological fixation
20
fixation failure
16
revision surgery
12
failure proximal-distal
12
proximal-distal mismatch
12
cementless stem
12
early revision
8
proximally coated
8
thigh pain
8
digital tomosynthesis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?