Improving the criterion validity of the activPAL in determining physical activity intensity during laboratory and free-living conditions.

J Sports Sci

Division of Kinesiology, School of Health and Human Performance, Faculty of Health, Dalhousie University, Halifax, Nova Scotia, Canada.

Published: April 2021

The activPAL is a valid measure of step counts and posture, but its ability to determine physical activity intensity is unclear. This study tested the criterion validity of the activPAL using its built-in linear cadence-metabolic equivalents (METs) equation (activPAL-linear) versus an individualized height-adjusted curvilinear cadence-METs equation (activPAL-curvilinear) to estimate intensity-related physical activity. Forty adults (25±6 years, 23.3±4.1 kg/m) wore an activPAL during a 7-stage progressive treadmill walking protocol (criterion: indirect calorimetry). A sub-sample (n=32) wore the device during free-living conditions for 7-days (criterion: PiezoRxD monitor). In the laboratory, the activPAL-linear overestimated METs during slow walking (1.5-3.0 miles•hour) but underestimated METs during fast walking (3.5-4.5 miles•hour) (all, p<0.001). In the free-living condition, the activPAL-linear overestimated time in light-intensity activity and underestimated moderate-intensity activity (both, p<0.001), but did not register any vigorous-intensity activity. In contrast, the activPAL-curvilinear estimated values statistically equivalent to indirect calorimetry for treadmill stages 1-6 (1.5-4.0 miles•hour) and to the PiezoRxD determined light- and moderate-intensity activity during free-living. We present a simple, data processing technique that uses an alternative curvilinear cadence-MET equation that improves the ability of the activPAL to measure intensity-related physical activity in both laboratory and free-living settings.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02640414.2020.1847503DOI Listing

Publication Analysis

Top Keywords

physical activity
12
criterion validity
8
validity activpal
8
activity intensity
8
free-living conditions
8
improving criterion
4
activpal
4
activpal determining
4
determining physical
4
intensity laboratory
4

Similar Publications

Objectives: Cardiac biomarkers are useful for the diagnostic and prognostic assessment of myocardial injury (MI) and heart failure. By measuring specific proteins released into the bloodstream during heart stress or damage, these biomarkers help clinicians detect the presence and extent of heart injury and tailor appropriate treatment plans. This study aims to provide robust biological variation (BV) data for cardiac biomarkers in athletes, specifically focusing on those applied to detect or exclude MI, such as myoglobin, creatine kinase-myocardial band (CK-MB) and cardiac troponins (cTn), and those related to heart failure and cardiac dysfunction, brain natriuretic peptide (BNP) and N-terminal brain natriuretic pro-peptide (NT-proBNP).

View Article and Find Full Text PDF

To accelerate the water dissociation in the Volmer step and alleviate the destruction of bubbles to the physical structure of catalysts during the alkaline hydrogen evolution, an integrated electrode of cobalt oxide and cobalt-molybdenum oxide grown on Ni foam, named CoO-Co2Mo3O8, is designed. This integrated electrode enhances the catalyst-substrate interaction confirmed by a micro-indentation tester, and thus hinders the destruction of the physical structure of catalysts caused by bubbles. Electrochemical testing shows the occurrence of a surface reconstruction of the integrated electrode, and CoO is transformed into Co(OH)2, denoted as Co(OH)2-Co2Mo3O8.

View Article and Find Full Text PDF

Background: Diaphragm thickness is a potential marker of sarcopenia in addition to muscle mass and strength at extremities. We aimed to clarify the descriptive epidemiology and prognostic significance of diaphragm thickness in the general population.

Methods: The study participants were 3324 community residents (mean age: 61.

View Article and Find Full Text PDF

Background: Alzheimer's disease (AD) is a progressive neurodegenerative disorder affecting millions worldwide, leading to cognitive and functional decline. Early detection and intervention are crucial for enhancing the quality of life of patients and their families. Remote Monitoring Technologies (RMTs) offer a promising solution for early detection by tracking changes in behavioral and cognitive functions, such as memory, language, and problem-solving skills.

View Article and Find Full Text PDF

Background: Iliac vein compression syndrome (IVCS) impedes venous blood return from the lower extremities due to iliac vein compression, manifesting as leg swelling, varicose veins, and thrombosis. These symptoms significantly degrade quality of life. Although iliac vein stenting provides symptomatic relief, the recovery process is protracted and fraught with challenges such as in-stent restenosis and psychological distress.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!