Motion tracking techniques have been extensively studied in recent years. However, capturing movements of the upper limbs is a challenging task. This document presents the estimation of arm orientation and elbow and wrist position using wearable flexible sensors (WFSs). A study was developed to obtain the highest range of motion (ROM) of the shoulder with as few sensors as possible, and a method for estimating arm length and a calibration procedure was proposed. Performance was verified by comparing measurement of the shoulder joint angles obtained from commercial two-axis soft angular displacement sensors (sADS) from Bend Labs and from the ground truth system (GTS) OptiTrack. The global root-mean-square error (RMSE) for the shoulder angle is 2.93 degrees and 37.5 mm for the position estimation of the wrist in cyclical movements; this measure of RMSE was improved to 13.6 mm by implementing a gesture classifier.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7696256 | PMC |
http://dx.doi.org/10.3390/s20226452 | DOI Listing |
BMC Anesthesiol
January 2025
Department of Anesthesiology, Perioperative Medicine and Pain Management, 1611 NW 12, University of Miami, Miami, FL, 33136, USA.
Background: Prolonged tracheal extubation time is defined as an interval ≥ 15 min from the end of surgery to extubation. An earlier study showed that prolonged extubations had a mean 12.4 min longer time from the end of surgery to operating room (OR) exit.
View Article and Find Full Text PDFISA Trans
December 2024
Electrical Engineering Department, Faculty of Engineering, Minia University, Minia 61111, Egypt. Electronic address:
The paper presents a new sensor-less voltage and frequency control method for a stand-alone doubly-fed induction generator (DFIG) feeding an isolated load. The proposed control approach directly regulates the magnitude and angle of the rotor-flux vector rather than controlling rotor currents or voltages as in classic field oriented control (FOC). To accurately regulate the magnitude and frequency of stator voltage, two separate closed-loop based PI regulators are employed to evaluate the reference signals of the rotor flux vector magnitude and angle, respectively.
View Article and Find Full Text PDFJ Surg Educ
January 2025
Department of Surgery, Division of General Surgery, Medical College of Wisconsin, Milwaukee, Wisconsin, Milwaukee, Wisconsin. Electronic address:
Objective: As COVID-19 restrictions are eased, there has been a lively debate on whether residency recruitment interviews should be held virtually or in-person. However, environmental impact has rarely been a focus of this debate and only by inference from limited survey data. In this study, we aimed to estimate the carbon emissions generated from air-travel versus in-person interviews in the general surgery residency recruitment.
View Article and Find Full Text PDFSci Rep
January 2025
NPSY.Lab-VR, Department of Human Sciences, University of Verona, Lungadige Porta Vittoria 17, Verona, Italy.
The Economy of action hypothesis postulates that bodily states rescale the perception of the individual's environment's spatial layout. The estimation of distances and slopes in navigation space (i.e.
View Article and Find Full Text PDFPhys Med
January 2025
Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan.
Background And Purpose: Free-breathing computed tomography (FBCT) used in treatment planning for lower thoracic (Th8-Th12) spine stereotactic body radiotherapy (SBRT) can cause deviations between planned and irradiated doses due to diaphragm movement (DM). This study analyzed the dosimetric impact of DM on lower thoracic spine SBRT.
Materials And Methods: Data were collected from 19 patients who underwent FBCT and four-dimensional CT (4DCT) during the same session.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!