Purpose: To evaluate differences in subjective and objective refractions in eyes with extended-depth-of-focus intraocular lenses (EDOF IOLs) using echelette optics, and the effect of the light wavelength used during examinations.

Methods: In the prospective study, subjective and objective refractions of 128 eyes of 64 patients were examined 3 months after implantation of the EDOF IOLs (ZXR00V, Johnson & Johnson Surgival Vision). Objective refractions were measured using an autorefractor with a near-infrared (NIR) light source. Clinical differences in the spherical, cylindrical and spherical equivalent (SE) refractions between the subjective and objective refractions were evaluated. Then, lens powers of monofocal, EDOF and diffractive bifocal IOLs in the use of a 850-nm light source were measured experimentally for using a lensmeter, and the differences from the monofocal IOLs were calculated.

Results: The mean objective refractions were more myopic (p < 0.001) than the subjective refractions; the differences in the spherical, cylindrical and SE refractions were -0.71, -0.26 and -0.84 dioptre, respectively. Experimental investigation resulted that there was the mean difference of 0.83 D with the EDOF from monofocal IOLs at 850 nm, while the difference was -0.20 D with bifocal IOLs.

Conclusions: The diffractive EDOF IOLs using echelette gratings inherently induced constant differences in the subjective and objective refractions, which arose from the chromatic difference in IOL powers for the visible and NIR lights.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8518701PMC
http://dx.doi.org/10.1111/aos.14660DOI Listing

Publication Analysis

Top Keywords

objective refractions
24
subjective objective
16
refractions eyes
8
eyes extended-depth-of-focus
8
extended-depth-of-focus intraocular
8
intraocular lenses
8
echelette optics
8
edof iols
8
light source
8
refractions
7

Similar Publications

Introduction: Workers who work in metallurgy factories processing aluminium are at risk of exposure to various kinds of metals and chemicals.

Objective: To describe sociodemographic characteristics and to find out morbidity profile of study participants .

Methods: A cross-sectional O bservational descriptive study was conducted in two aluminium processing metallurgy factories in Howrah district of Indian state of West Bengal.

View Article and Find Full Text PDF

Importance: Additional data are required regarding atropine treatment regimens for control of myopia progression.

Objective: To investigate the efficacy and safety of different atropine regimens for myopia in children.

Design, Setting, And Participants: This was a secondary analysis of the 3-year results of the 24-Month Myopia Outcome Study of Atropine in Children (MOSAIC) trial, called the MOSAIC2 trial.

View Article and Find Full Text PDF

Purpose: To compare the clinical outcomes, surgical workflow, and patient satisfaction following small incision lenticule extraction (SMILE) performed with the VisuMax 800 in one eye and the VisuMax 500 in the contralateral eye (both Carl Zeiss Meditec).

Methods: This was a prospective, single-site clinical study of patients undergoing SMILE for myopia and myopic astigmatism between February 2022 and August 2023. Each patient underwent bilateral treatment using the VisuMax 800 (VM800 group) in one eye and the VisuMax 500 (VM500 group) in the contralateral eye.

View Article and Find Full Text PDF

Electrochemical In Situ Characterization Techniques in the Field of Energy Conversion.

Small Methods

January 2025

Institute of Materials Research, Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, P. R. China.

With the proposal of the "carbon peak and carbon neutrality" goals, the utilization of renewable energy sources such as solar energy, wind energy, and tidal energy has garnered increasing attention. Consequently, the development of corresponding energy conversion technologies has become a focal point. In this context, the demand for electrochemical in situ characterization techniques in the field of energy conversion is gradually increasing.

View Article and Find Full Text PDF

Exploring Occupational Health Challenges in Pathology: A Cross-Sectional Survey of Indian Pathologists.

Cureus

December 2024

Pathology, BLDE (Deemed to be University) Shri B.M. Patil Medical College, Hospital, and Research Centre, Vijayapura, IND.

Introduction Occupational health hazards are a significant concern for pathologists due to their unique work environment. These professionals face risks from prolonged microscope use, exposure to chemicals such as formalin, and handling sharp instruments, leading to issues such as musculoskeletal disorders and needlestick injuries. Addressing these hazards is crucial for their well-being and the overall efficiency of medical diagnostics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!