Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Orally administered angiotensin II receptor blockers (ARBs) decrease intraocular pressure (IOP). Topical administration may reduce systemic side effects and result in a useful glaucoma drug. The aim of this study is to test the ocular delivery and pharmacologic effect of nanoparticle eye drops containing ARBs (e.g. irbesartan and candesartan).
Methods: 1.5% irbesartan and 0.15% candesartan eye drops were applied to rabbits. The pharmacokinetics in cornea and aqueous humour after single eye drop application were studied in 49 rabbits. The effect of the eye drops on IOP was studied in 10 rabbits using an iCare (® TonoVet Plus, iCare, Finland) tonometer and compared with 0.5% timolol eye drops.
Results: Candesartan lowered IOP from 24.6 ± 5.1 mmHg at baseline to 19.0 ± 2.9 mmHg (mean ± SD, p = 0.030, n = 10) 4 hr after application. Irbesartan lowered IOP from 24.2 ± 1.7 mmHg to 20.2 ± 0.9 mmHg (p = 0.14, n = 10). Timolol decreased the IOP from 24.9 ± 4.2 mmHg to 20.4 ± 4.8 mmHg (mean ± SD, p = 0.036, n = 10). The pharmacokinetics data show that both formulations deliver effective amounts of drug into the intraocular tissues, with irbesartan and candesartan reaching concentrations of 121 ± 69 and 30.43 ± 13.93 ng/g (mean ± SD), respectively, in the aqueous humour 3 hr after a single-dose administration.
Conclusions: Topical application of irbesartan and candesartan eye drops delivers effective drug concentrations to the anterior segment of the eye in rabbits, achieving drug concentrations 100 times above the IC50 for angiotensin II receptor and showing an IOP-lowering effect. Angiotensin receptor blocker (ARB) eye drops have potential as a new class of glaucoma drugs.