A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of magnetic particle-based chemiluminescence immunoassay for measurement of human procalcitonin in serum. | LitMetric

Background: Serum procalcitonin (PCT) has been recognized as a primary biomarker in bacterial infections, and monitoring its concentration could help to evaluate the prognosis of sepsis and guide the antibiotic administration. We aimed to establish a fast and accurate immunoassay for PCT quantitation.

Methods: Our newly developed monoclonal antibodies (mAbs) against human PCT were preliminarily evaluated by enzyme-linked immunosorbent assay and then used to develop a chemiluminescence enzyme immunoassay (CLEIA). The proposed CLEIA was assessed in analytical performance and applied to measurement of serum PCT.

Results: mAb 2D3 and mAb 8F6 were selected as capture and detection antibody respectively, due to the highest sensitivity for PCT detection with no cross reaction to calcitonin gene-related peptides. The proposed CLEIA based on mAb pair of 2D3/8F6-AP was characterized for a working range from 0.03 to 100 μg/L. An excellent correlation was observed between our proposed assay and the VIDAS BRAHMS PCT assay (r: 0.9825).

Conclusion: Our newly developed mAbs and CLEIA can serve as important diagnostic tools for measurement of human PCT in serum.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jim.2020.112913DOI Listing

Publication Analysis

Top Keywords

measurement human
8
newly developed
8
human pct
8
proposed cleia
8
pct
6
development magnetic
4
magnetic particle-based
4
particle-based chemiluminescence
4
chemiluminescence immunoassay
4
immunoassay measurement
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!