Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A dual signal and label-free electrochemical aptasensor for mucin 1 was constructed based on hemin/graphene@PdPtNPs nanocomposite (H-Gr@PdPtNPs). Hemin attached on the graphene surface not only improves the solubility of graphene and acts as an in-situ electrochemical probe but also exhibits excellent peroxidase-like properties to electrocatalyze the reduction of HO. PdPtNPs also show outstanding catalytic capacity to the reduction of HO and provide numerous binding sites for loading dDNA (mucin 1 aptamer and cDNA) to form the sensing interface. In the presence of mucin 1, due to the specific affinity between aptamer and mucin 1, double helix would be induced dissociation and the aptamer would be pulled off from the electrode. As a result, the electrochemical signals of hemin and HO were recovered. Based on these properties, the label-free and sensitive dual signal electrochemical biosensor for mucin 1 detection has been developed. The one is differential pulse voltammetry (DPV) signal of hemin and the other is chronoamperometry signal arisen from the catalytic reduction of HO. The linear ranges for mucin 1 were 8.0 pg mL to 80 ng mL and 0.8 pg mL to 80 ng mL with the limit of detection 2.5 pg mL and 0.25 pg mL by DPV and chronoamperometry, respectively. The recovery of mucin 1 in human blood serum samples was from 95.0% to 104.2%. The detection platform does not need signal labeling which greatly reduced the sophisticated and expensive procedures. The aptasensor provide a promising strategy for the determination of mucin 1 in clinical diagnostics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2020.112785 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!