Liver grafts from pediatric donors represent a small fraction of grafts transplanted into adult recipients, and their use in adults requires special consideration of donor size to prevent perioperative complications. In the past, graft weight or volume ratios have been adopted from the living donor liver transplant literature to guide clinicians; however, these metrics are not regularly available to surgeons accepting deceased donor organs. In this study, we evaluated all pediatric-to-adult liver transplants in the United Network for Organ Sharing Standard Transplant Analysis and Research database from 1987 to 2019, stratified by donor age and donor-recipient height mismatch ratio (HMR; defined as donor height/recipient height). On multivariable regression controlling for cold ischemia time, age, and transplantation era, the use of donors from ages 0 to 4 and 5 to 9 had increased risk of graft failure (hazard ratio [HR], 1.81 [P < 0.01] and HR, 1.16 [P < 0.01], respectively) compared with donors aged 15 to 17. On Kaplan-Meier survival analysis, a HMR < 0.8 was associated with inferior graft survival (mean, 11.8 versus 14.6 years; log-rank P < 0.001) and inferior patient survival (mean, 13.5 versus 14.9 years; log-rank P < 0.01) when compared with pairs with similar height (HMR, 0.95-1.05; ie, donors within 5% of recipient height). This study demonstrates that both young donor age and low HMR confer additional risk in adult recipients of pediatric liver grafts.

Download full-text PDF

Source
http://dx.doi.org/10.1002/lt.25937DOI Listing

Publication Analysis

Top Keywords

donor-recipient height
8
height mismatch
8
pediatric-to-adult liver
8
liver transplant
8
donor
5
mismatch associated
4
associated decreased
4
decreased survival
4
survival pediatric-to-adult
4
liver
4

Similar Publications

Prediction of Whole Liver Graft Weight Based on Biometric Variables in Paediatric and Adult Liver Donors.

Children (Basel)

October 2024

Department of Paediatric Surgery, Assistance Publique-Hôpitaux de Paris, Université Paris-Saclay, Bicêtre Hospital, 78 Rue du Général Leclerc, 94270 Le Kremlin Bicêtre, France.

Background/objectives: In paediatric liver transplantation, donor-recipient compatibility depends on graft size. We explored whether the graft weight can be predicted using the donor's biometric parameters.

Methods: We used seven easily available biometric variables in 142 anonymised paediatric and adult donors, with data collected between 2016 and 2022.

View Article and Find Full Text PDF

Objective: This study aimed to investigate the impact of the donor-recipient BMI ratio on the survival outcomes of heart transplant recipients.

Methods: A retrospective analysis was conducted on 641 heart transplant patients who underwent surgery between September 2008 and June 2021. The BMI ratio (donor BMI divided by recipient BMI) was calculated for each patient.

View Article and Find Full Text PDF

Artificial intelligence-driven automated lung sizing from chest radiographs.

Am J Transplant

August 2024

Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.

Lung size measurements play an important role in transplantation, as optimal donor-recipient size matching is necessary to ensure the best possible outcome. Although several strategies for size matching are currently used, all have limitations, and none has proven superior. In this pilot study, we leveraged deep learning and computer vision to develop an automated system for generating standardized lung size measurements using portable chest radiographs to improve accuracy, reduce variability, and streamline donor/recipient matching.

View Article and Find Full Text PDF

Background: Lung transplantation (LTx) is a crucial therapeutic strategy for patients suffering from end-stage respiratory diseases, necessitating precise donor-recipient size matching to ensure optimal graft function. While standard allocation protocols rely on predicted lung capacity based on factors such as sex, age, and height, a subset of patients with respiratory diseases presents an additional challenge - thoracic or vertebral deformities. These deformities can complicate accurate volume predictions and may impact the success of lung transplantation.

View Article and Find Full Text PDF

Background: Donor/recipient size matching is paramount in heart transplantation. Body weight, height, body mass index, body surface area, and predicted heart mass (PHM) ratios are generally used in size matching. Precise size matching is important to achieve better clinical outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!