Pulsed micro-arc oxidation (MAO) in a strongly alkaline electrolyte (pH > 13), consisting of NaSiO⋅9HO and NaOH, was used to form a thin porous oxide coating consisting of two layers differing in chemical and phase composition. The unique procedure, combining MAO and removal of the outer layer by blasting, enables to prepare a coating suitable for application in temporary traumatological implants. A bilayer formed in an alkaline electrolyte environment during the application of MAO enables the formation of a wear-resistant layer with silicon incorporated in the oxide phase. Following the removal of the outer rutile-containing porous layer, the required coating properties for traumatological applications were determined. The prepared surfaces were characterized by scanning electron microscopy, X-ray diffraction patterns, X-ray photoelectron spectroscopy, atomic force microscopy and contact angle measurements. Cytocompatibility was evaluated using human osteoblast-like Saos-2 cells. The newly-developed surface modifications of Ti-6Al-4V ELI alloy performed satisfactorily in all cellular tests in comparison with MAO-untreated alloy and standard tissue culture plastic. High cell viability was supported, but the modifications allowed only relatively slow cell proliferation, and showed only moderate osseointegration potential without significant support for matrix mineralization. Materials with these properties are promising for utilization in temporary traumatological implants.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7666130PMC
http://dx.doi.org/10.1038/s41598-020-76448-wDOI Listing

Publication Analysis

Top Keywords

traumatological implants
12
alkaline electrolyte
12
micro-arc oxidation
8
removal outer
8
temporary traumatological
8
preparation highly
4
highly wettable
4
wettable coatings
4
coatings ti-6al-4v
4
ti-6al-4v eli
4

Similar Publications

Background: Total ankle arthroplasty (TAA) is an effective treatment for severe end-stage ankle osteoarthritis (AO). Despite satisfactory results, range of motion (ROM) is still suboptimal compared to healthy ankles. This issue may stem from different conditions, and the difficulty in accurately restoring the height of the joint line may be one of them.

View Article and Find Full Text PDF

Purpose: Following failed internal fixation of intertrochanteric fractures (FIF-ITF), the decision to use a long-stem or standard-stem femoral implant in hip arthroplasty is still debated. This study aimed to explore how the healing status of fractures after FIF-ITF failure affects the choice of femoral stem and clinical outcomes.

Methods: Our retrospective cohort study reviewed 105 cases of patients with FIF-ITF who underwent hip arthroplasty at three tertiary Grade A hospitals between December 2012 and December 2022.

View Article and Find Full Text PDF

Local antimicrobial delivery systems for prophylaxis and treatment of periprosthetic traumatological infections.

Eur J Pharm Sci

January 2025

Department of Pharmaceutics and Food Technology, Faculty of Pharmacy, Complutense University of Madrid, Plaza Ramón y Cajal, 28040, Madrid, Spain; Institute of Industrial Pharmacy, Complutense University Madrid, 28040, Madrid, Spain. Electronic address:

Infections associated with implants are the most serious complications in joint replacement surgeries and can jeopardize the functionality of orthopedic implants. Local antimicrobial delivery could enable antibiotics to attain concentrations above the minimum inhibitory concentration (MIC) threshold at the joint replacement site while preventing systemic side effects. Therefore, there is a dire need for the development of improved biomaterial-based delivery systems for local antibiotic administration in prosthetic infections.

View Article and Find Full Text PDF

Purpose: For preserving the humeral bone stock, some surgeons proposed a stemless humeral prosthetic component. This study reports the functional and radiologic results of the stemless anatomic prosthesis Simpliciti*(Tornier, Wright, Stryker), with the hypothesis that it can achieve a good metaphyseal fixation.

Methods: 28 patients underwent 30 shoulder replacements with the Simpliciti* humeral prosthesis followed for an average of three years (2 months to 8 years).

View Article and Find Full Text PDF

[Standard radiographic images in cephalomedullary nailing fixation for intertrochanteric femoral fractures].

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi

September 2024

Department of Orthopedic Trauma, Zhongda Hospital, Southeast University, Nanjing Jiangsu, 210009, P. R. China.

Objective: To review and summarize the projections of radiographic images during cephalomedullary nailing fixation for intertrochanteric femoral fractures, and to propose a set of three projections as standard requirement in immediate postoperative fluoroscopy.

Methods: Papers on intertrochanteric femoral fractures treated with cephalomedullary nailing fixation that published in a three-year period of 2021-2023 in four leading English orthopedic trauma journals were searched in PubMed. The presented radiographic pictures were identified and scrutinized as whether they were in standard anteroposterior and/or lateral projections of the implanted nails.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!