Background: Molecular targeted contrast-enhanced ultrasound (CEUS) imaging is a potential imaging strategy to improve the diagnostic accuracy of conventional ultrasound (US) imaging. US contrast agents are usually micrometer-sized and non-target gas bubbles while nano-sized and targeted agents containing phase-shift materials absorb more attractions for their size and the liquid core and excellent molecular imaging effect.
Methods: PLGA12k-mPEG2k-NH2, DSPE-mPEG2k and perfluorohexan (PFH) were used to construct a new targeted ultrasound contrast agent with CUB domain-containing protein 1 (CDCP1) receptor for the detection and diagnosis of prostate cancer. The potential of tumor-targeted nanoparticles (CDCP1-targeted perfluorohexan-loaded phase-transitional nanoparticles, anti-CDCP1 NPs) as contrast agents for ultrasound (US) imaging was assessed in vitro. Moreover, studies on the cytotoxicity and the targeting ability of anti-CDCP1 NPs assisted by US were carried out.
Results: The results showed that anti-CDCP1 NPs had low cytotoxicity, and with the increasing of polymer concentration in anti-CDCP1 NPs, the CEUS imaging of agent gradually enhanced, and enhanced imaging associated with the length of observing time. Furthermore, it was testified that anti-CDCP1 assisted the agent to target cells expressing CDCP1, which demonstrated the active targeting of anti-CDCP1 NPs in vitro.
Conclusion: All in all, the feasibility of using targeted anti-CDCP1 NPs to enhance ultrasound imaging has been demonstrated in vitro, which laid a solid foundation for molecular US imaging in vivo, and anti-CDCP1 NPs might have a great clinical application prospect.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3233/CH-200900 | DOI Listing |
Clin Hemorheol Microcirc
February 2022
State Key Laboratory of Oncogenes and Related Genes, Shanghai Cancer Institute, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, People's Republic of China.
Background: Molecular targeted contrast-enhanced ultrasound (CEUS) imaging is a potential imaging strategy to improve the diagnostic accuracy of conventional ultrasound (US) imaging. US contrast agents are usually micrometer-sized and non-target gas bubbles while nano-sized and targeted agents containing phase-shift materials absorb more attractions for their size and the liquid core and excellent molecular imaging effect.
Methods: PLGA12k-mPEG2k-NH2, DSPE-mPEG2k and perfluorohexan (PFH) were used to construct a new targeted ultrasound contrast agent with CUB domain-containing protein 1 (CDCP1) receptor for the detection and diagnosis of prostate cancer.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!