We present a high-resolution microscope capable of imaging buried structures through optically opaque materials with micrometer transverse resolution and a nanometer-scale depth sensitivity. The ability to image through such materials is made possible by the use of laser ultrasonic techniques, where an ultrafast laser pulse launches acoustic waves inside an opaque layer and subsequent acoustic echoes from buried interfaces are detected optically by a time-delayed probe pulse. We show that the high frequency of the generated ultrasound waves enables imaging with a transverse resolution only limited by the optical detection system. We present the imaging system and signal analysis and demonstrate its imaging capability on complex microstructured objects through 200 nm thick metal layers and gratings through 500 nm thickness. Furthermore, we characterize the obtained imaging performance, achieving a diffraction-limited transverse resolution of 1.2 μm and a depth sensitivity better than 10 nm.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.405875DOI Listing

Publication Analysis

Top Keywords

transverse resolution
12
optically opaque
8
depth sensitivity
8
imaging
5
high-resolution microscopy
4
microscopy optically
4
opaque media
4
media ultrafast
4
ultrafast photoacoustics
4
photoacoustics high-resolution
4

Similar Publications

Objective: This study aims to analyze anatomical parameters of the transmission route of sigmoid sinus tinnitus (SST) to explore its mechanism and speculate on possible responsible anatomical abnormalities.

Methods: Clinical data were retrospectively collected from SST and sigmoid sinus wall dehiscence (SSWD) patients suggested by temporal bone high resolution computed tomography (HRCT), with and without tinnitus, at the First Affiliated Hospital of Chongqing Medical University from January 2015 to August 2022. Patients were divided into SSWD tinnitus ( = 61), and non-tinnitus ( = 60) groups based on HRCT features.

View Article and Find Full Text PDF

Purpose: Pulmonary MRI faces challenges due to low proton density, rapid transverse magnetization decay, and cardiac and respiratory motion. The fermat-looped orthogonally encoded trajectories (FLORET) sequence addresses these issues with high sampling efficiency, strong signal, and motion robustness, but has not yet been applied to phase-resolved functional lung (PREFUL) MRI-a contrast-free method for assessing pulmonary ventilation during free breathing. This study aims to develop a reconstruction pipeline for FLORET UTE, enhancing spatial resolution for three-dimensional (3D) PREFUL ventilation analysis.

View Article and Find Full Text PDF

Aim: Left atrial (LA) strain is emerging as a valuable metric for evaluating cardiac function, particularly under pathological conditions such as pressure overload. This preclinical study investigates the predictive utility of LA strain on cardiac function in a murine model subjected to pressure overload, mimicking pathologies such as hypertension and aortic stenosis.

Methods: High-resolution ultrasound was performed in a cohort of mice (n = 16) to evaluate left atrial and left ventricular function at baseline and 2 and 4 weeks after transverse aortic constriction (TAC).

View Article and Find Full Text PDF

What is the frequency of anterior syndesmosis injury in posterior malleolus fracture?

J Orthop Surg Res

January 2025

Department of Orthopedics and Rheumoorthopedics, Centre of Postgraduate Medical Education, Prof. Adam Gruca Orthopedic and Trauma Teaching Hospital, Konarskiego 13, Otwock, 05-400, Poland.

Background: Posterior malleolus fractures may be fixed to restore syndesmosis stability. However, these fractures are often accompanied by ruptures of other ligaments that stabilize the syndesmosis. This study investigates the frequency of anterior syndesmosis injury in posterior malleolus fractures and its effect on rotational stability.

View Article and Find Full Text PDF

Fourier ptychographic microscopy (FPM) enables high-resolution, wide-field imaging of both amplitude and phase, presenting significant potential for applications in digital pathology and cell biology. However, artifacts commonly observed at the boundaries of reconstructed images can significantly degrade imaging quality and phase retrieval accuracy. These boundary artifacts are typically attributed to the use of the fast Fourier transform (FFT) on non-periodic images.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!