Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
BMS-986142 has been developed as an innovative Bruton's tyrosine kinase inhibitor for treatment of several autoimmune diseases. The drug substance of BMS-986142 may contain three potential atropisomeric impurities due to its unique structural characteristics. Developing a single liquid chromatography (LC) method to separate all four highly structurally related atropisomers and other process impurities from each other turned out to be a daunting task. Two-dimensional LC (2DLC) was found to be an extremely powerful enabling technology for extracting purity information out of the complex sample impurity profile and facilitated process development before a final single dimension method was discovered. The off-the-shelf 2DLC instrument could be configured to allow injection of the targeted first dimension peak through either no-loss multiple heart-cutting fractions or as a large, single volume fraction with on-line dilution. Excellent precision (relative standard deviation of 0.3 %) and recovery (101.2 ± 0.2 %) was achieved for an atropisomer impurity at a 10 % monitoring level in the first configuration with sensitivity down to 0.2 % w/w. With the second instrument configuration, which eliminated the need for fraction recombination, similar figures of merit were maintained for the second dimension at the cost of losing the ability to collect and park multiple fractions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2020.113730 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!