AI Article Synopsis

Article Abstract

Analyze "number of nodes" as an integer-valued variable to identify possible minimum lymph node (LN) number to sample during lung cancer resection. The National Cancer Database (NCDB) queried 2004-14 for surgically treated clinical stage I/II non-small-cell lung cancer (NSCLC). Overall survival (OS) by number of LN sampled was examined for the complete dataset, by adenocarcinoma, and by degree of resection using number of sampled LN both as integer-valued (0-30 nodes) variable and collapsed into classes. A total of 102,225 patients were analyzed. Median sampled LNs were 7. Median overall survival was 59 months if no LNs were sampled (95% confidence interval [CI]: 57.0-62.4), 74.7 months for 1 sampled LN (95% CI: 69.6-78.1), 80.2 (95% CI: 74.2-85.6) for 2 sampled LN, up to 81.5 mos. for 29 sampled LN. A Cox regression model using "0 LN" as baseline level, showed association with increased overall survival starting at 1 LN (hazard ratio [HR] 0.81, 95% CI 0.76-0.87; P <0.001). A "moving baseline" Cox regression model, showed no additional benefit when sampling additional nodes. We noticed a decreasing, linear association between OS and a number of 0-5 sampled LNs, most pronounced between 0 and 1 LN sampled, using a martingale residual plot from a null Cox model; no association was observed for more sampled LNs. For patients undergoing lobectomy, difference in OS was noted between 0 and 1LN sampled but not between 2 and 30 LN. These differences were not statistically significant until the number of 4 removed LN (respectively 3 for wedge-resections). For segmentectomies, median survival was not statistically associated with number of LN sampled. Based on NCDB data, LN sampling for lung cancer resections is recommended. Lobectomy survival is positively associated with 4 LN sampled, but ideal sampling may lie at 5LN in most cases. NCDB data does not seem to justify the quality metric of minimum 10 LNs.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.semtcvs.2020.11.007DOI Listing

Publication Analysis

Top Keywords

lung cancer
12
lymph node
8
non-small-cell lung
8
number sampled
8
sampled 95%
8
sampled
7
analysis lymph
4
node sampling
4
sampling minimums
4
minimums early
4

Similar Publications

Feasibility of detecting non-small cell lung cancer using exhaled breath condensate metabolomics.

J Breath Res

January 2025

School of Medicine and Pharmacy, Ocean University of China, 5 Yushan Rd, Qingdao, Shandong, 266003, CHINA.

Lung cancer is one of the most common malignancy in the world, and early detection of lung cancer remains a challenge. The exhaled breath condensate (EBC) from lung and trachea can be collected totally noninvasively. In this study, our aim is to identify differential metabolites between non-small cell lung cancer (NSCLC) and control EBC samples and discriminate NSCLC group from control group by orthogonal projections to latent structures-discriminant analysis (OPLS-DA) models.

View Article and Find Full Text PDF

Substantial epidemiological evidence suggests a significant correlation between particulate matter 2.5 (PM) and lung cancer. However, the mechanism underlying this association needs to be further elucidated.

View Article and Find Full Text PDF

A previous study classifies solid tumors based on collagen deposition and immune infiltration abundance, identifying a refractory subtype termed armored & cold tumors, characterized by elevated collagen deposition and diminished immune infiltration. Beyond its impact on immune infiltration, collagen deposition also influences tumor angiogenesis. This study systematically analyzes the association between immuno-collagenic subtypes and angiogenesis across diverse cancer types.

View Article and Find Full Text PDF

Breath analysis is increasingly recognized as a powerful noninvasive diagnostic technique, and a plethora of exhaled volatile biomarkers have been associated with various diseases. However, traditional analytical methodologies are not amenable to high-throughput diagnostic applications at the point of need. An optical spectroscopic technique, surface-enhanced Raman spectroscopy (SERS), mostly used in the research setting for liquid sample analysis, has recently been applied to breath-based diagnostics.

View Article and Find Full Text PDF

The increasing shift from cannabis smoking to cannabis vaping is largely driven by the perception that vaping to form an aerosol represents a safer alternative to smoking and is a form of consumption appealing to youth. Herein, we compared the chemical composition and receptor-mediated activity of cannabis smoke extract (CaSE) to cannabis vaping extract (CaVE) along with the biological response in human bronchial epithelial cells. Chemical analysis using HPLC and GC/MS revealed that cannabis vaping aerosol contained fewer toxicants than smoke; CaSE and CaVE contained teratogens, carcinogens, and respiratory toxicants.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!