Purpose: We investigated the recovery and extraction efficiency of DNA from three metal surfaces (brass, copper, steel) relevant to forensic casework, and plastic (control) using two different swabbing systems; Rayon and Isohelix™ swabs, with sterile water and isopropyl alcohol respectively, as the wetting solutions.
Methods: Twenty nanograms of human genomic DNA were applied directly to Isohelix™ and Rayon swabs; and to the metal and plastic substrates. All substrates were left to dry for 24 h, followed by single wet swabbing and extraction with the DNA IQ™ System. DNA extracts were quantified using real time quantitative PCR assays with SYBR green chemistry.
Results: DNA was extracted from directly seeded Isohelix™ swabs with a high efficiency of 98%, indicating effective DNA-release from the swab into the extraction buffer. In contrast, only 58% of input DNA was recovered from seeded Rayon swabs, indicating higher DNA retention by these swabs. Isohelix™ swabs recovered 32 - 53% of DNA from metal surfaces, whilst the Rayon swabs recovered 11-29%. DNA recovery was lowest from copper and highest from brass. Interestingly, Rayon swabs appeared to collect more DNA from the plastic surface than Isohelix™ swabs, however, due to the lower release of DNA from Rayon swabs they returned less DNA overall following extraction than Isohelix™ swabs.
Conclusion: These results demonstrate that DNA samples deposited on metal surfaces can be more efficiently recovered using Isohelix™ swabs wetted with isopropyl alcohol than Rayon swabs wetted with sterile water, although recovery is affected by the substrate type.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12024-020-00329-x | DOI Listing |
Viruses
July 2024
Department of Medicine and Epidemiology, School of Veterinary Medicine, University of California, Davis, CA 95616, USA.
J Forensic Sci
May 2024
College of Science and Engineering, Flinders University, Adelaide, South Australia, Australia.
Plastic bags, such as ziplock bags, have been used to transport illicit materials worldwide; however, very few studies have tried to optimize the recovery of DNA from these items. This study reports on the best combination of swabs and moistening solution for the greatest recovery of cellular material from ziplock bags. Five swabs, two different variations of Copan Diagnostics nylon 4N6FLOQSwabs, one Medical Wire rayon DRYSWAB, one IsoHelix rayon swab, and one Livingstone cotton swab, were evaluated with two moistening solutions, Triton X-100 in either distilled water or isopropanol.
View Article and Find Full Text PDFJ Pers Med
October 2023
Biocel UK Ltd., Hull HU10 6TS, UK.
Saliva is a largely unexplored liquid biopsy that can be readily obtained noninvasively. Not dissimilar to blood plasma or serum, it contains a vast array of bioconstituents that may be associated with the absence or presence of a disease condition. Given its ease of access, the use of saliva is potentially ideal in a point-of-care screening or diagnostic test.
View Article and Find Full Text PDFJ Pers Med
June 2023
Biocel UK Ltd., Hull HU10 6TS, UK.
There is an increasing need for inexpensive and rapid screening tests in point-of-care clinical oncology settings. Herein, we develop a swab "dip" test in saliva obtained from consenting patients participating in a lung-cancer-screening programme being undertaken in North West England. In a pilot study, a total of 211 saliva samples ( = 170 benign, 41 designated cancer-positive) were randomly taken during the course of this prospective lung-cancer-screening programme.
View Article and Find Full Text PDFTaiwan J Obstet Gynecol
March 2023
Infectious Disease and Clinical Microbiology, Ankara Yildırım Beyazit University, Ankara City Hospital, Ankara, Turkey.
Objective: It is important to determine the presence of SARS-CoV-2 in the vaginal fluid samples of reproductive-aged women with severe disease during the acute stage of the disease and to determine the risks of transmission by sexual or vertical transmission.
Material And Methods: Adult women with confirmed severe COVID-19 who were admitted to Ankara City Hospital intensive care unit (ICU) between December 1st, 2020, and January 1st, 2021, were enrolled in the study. Vaginal swab samples were collected within 48 h in the ICU using Dacron or rayon swabs and tested for SARS-CoV-2 using reverse transcription real-time polymerase chain reaction (RT PCR).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!