A 3-year review of MRI safety incidents within a UK independent sector provider of diagnostic services.

BJR Open

Christie Medical Physics and Engineering, The Christie NHS Trust, Manchester, UK.

Published: April 2019

A review of MRI safety incidents conducted over a 3-year period for a large independent sector diagnostic imaging provider in the UK. The review took a systematic approach using reports logged on an internal incident reporting system that were then categorised and analysed for themes and trends. Notable cases and actions taken are also described from within the period. MRI safety-related events made up 7.5% of the total number of incident reports submitted and 15.5% of all MRI-related reports. The MR safety-related incidence report rate was 0.05% (1 per 1987 patients), which is relatively low considering the number of patients seen in our facilities each day. Internal MRI safety events indicated the main trends to be around referral of contraindicated devices (32% of reports) and failure in the screening process (21.5%-either due to unexpected implants or being unable to confirm safety). To improve practice and work to reduce incidents, advice and instructional materials were developed. The review suggests a potential approach to categorisation of MRI-related safety events which could allow comparisons to be made across organisations, helping to look for trends and guide learning. It also provides insight into the state of MRI safety within the organisation, a rationale for some of the interventions introduced to improve safety, and discussion around common issues arising in MRI safety.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7592402PMC
http://dx.doi.org/10.1259/bjro.20180006DOI Listing

Publication Analysis

Top Keywords

mri safety
20
review mri
8
safety
8
safety incidents
8
independent sector
8
safety events
8
mri
6
3-year review
4
incidents independent
4
sector provider
4

Similar Publications

MRI-guided focal laser ablation (MRI-FLA) is an emerging minimally invasive technique for treating localized prostate tumors, aiming to provide effective cancer control while minimizing side effects. This meta-analysis systematically evaluates the clinical outcomes, technical efficacy, and complication rates associated with MRI-FLA to better understand its therapeutic potential and safety profile in prostate cancer management. In July 2024, PubMed (MEDLINE) was searched for eligible trials using the PRISMA guidelines.

View Article and Find Full Text PDF

Background: T thermometry is considered a straight method for the safety monitoring of patients with deep brain stimulation (DBS) electrodes against radiofrequency-induced heating during Magnetic Resonance Imaging (MRI), requiring different sequences and methods.

Objective: This study aimed to compare two T thermometry methods and two low specific absorption rate (SAR) imaging sequences in terms of the output image quality.

Material And Methods: In this experimental study, a gel phantom was prepared, resembling the brain tissue properties with a copper wire inside.

View Article and Find Full Text PDF

Objective: The study aims to compare ChatGPT and Google Gemini-generated patient education guides regarding claustrophobia during MRI, mammography screening, and MR safe and unsafe items and the importance of knowing what items can be carried into an MR room.

Methods: The study utilized ChatGPT 3.5 and Google Gemini to create patient education guides concerning claustrophobia during MRI, mammography screening, and MR safe and unsafe items.

View Article and Find Full Text PDF

PEARL: A Multicenter Phase 2 Study of Lorlatinib in Patients with ALK-Rearranged NSCLC and Central Nervous System Disease.

Clin Lung Cancer

December 2024

Guangdong Lung Cancer Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China. Electronic address:

Background: Patients with ALK-rearranged non-small cell lung cancer (ALK+ NSCLC) with symptomatic brain (BM) and leptomeningeal (LM) metastases are underrepresented in clinical trials due to poor performance status. Additionally, the need for improved and validated assessment criteria for evaluating central nervous system (CNS) response remains critical. Lorlatinib has demonstrated systemic activity in patients with ALK+ NSCLC.

View Article and Find Full Text PDF

Treating colorectal liver metastases (CLMs) located at the hepatocaval confluence with surgery is challenging due to its complexity and associated high risks of perioperative mortality and morbidity. Moreover, thermal ablation techniques are sensitive to the "heat-sink" effect, which reduces their efficacy when tumors are in contact with major blood vessels. In this study we evaluated the feasibility and safety of an intraoperative high-intensity focused ultrasound (HIFU) device for destroying liver tissue volumes sufficiently large to consider treating CLMs at the hepatocaval confluence.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!