Background: It is unknown whether locking or nonlocking superior plate fixation is better for managing displaced midshaft clavicle fractures. Therefore, we aimed to compare the clinical and radiographic outcomes of locking and nonlocking superior plate fixation of displaced midshaft clavicle fractures.

Methods: A total of 102 consecutive patients with displaced midshaft clavicle fractures (2B1 and 2B2 in Robinson classification) participated in this randomized controlled trial; 12 patients were excluded. Surgeries were performed using a 3.5-mm Locking Compression Plate (LCP) between 2007 and 2015. Patients were treated either with a locking plate (group L, n = 45) or a nonlocking plate (group N, n = 45). In both groups, the plates were fixed to the proximal and distal clavicle with two and/or three screws, respectively. The main outcome measures were complication rates, time to bone union, and Constant score.

Results: Forty-two patients in group L (mean age, 45.9 years) and 41 in group N (mean age, 43.6 years) were followed. The overall complication rates in groups L and N were 7.2% (three peri-implant fractures) and 7.3% (non-union, deformed plate, and peri-implant fracture), respectively (p = .98). The average time to union significantly differed between groups (L vs. N: 13.0 ± 4.1 vs. 17.5 ± 6.3 weeks; p < .01). However, the Constant score at the final follow-up was not significantly different between groups (L vs. N: 87.0 ± 12.3 vs. 89.8 ± 9.1).

Conclusions: Similar complication rates and clinical results were found for locking and nonlocking superior plate fixation for displaced midshaft clavicle fractures. However, the time to bone union was shorter with the locking plate. This study suggests that both plating systems are effective for treating displaced midshaft clavicle fractures.

Level Of Evidence: Therapeutic, level I.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jos.2020.09.017DOI Listing

Publication Analysis

Top Keywords

displaced midshaft
16
midshaft clavicle
16
nonlocking superior
12
superior plate
12
clavicle fractures
12
locking nonlocking
8
plate fixation
8
plate group
8
group n = 45
8
complication rates
8

Similar Publications

In this report, we present a case of a triple clavicle injury, acromioclavicular joint (ACJ) dislocation, a middle third clavicle fracture, and a sternoclavicular joint (SCJ) subluxation, and describe its successful surgical treatment. A 49-year-old female patient sustained a 3 m fall, resulting in direct trauma to her left shoulder. Initial radiographs and computed tomography (CT) scans revealed a displaced middle third clavicle fracture, a high-grade ACJ dislocation, and a posterior SCJ subluxation.

View Article and Find Full Text PDF

Introduction: Clavicle fractures are routinely encountered in orthopedic clinical practice and have often been the subject of debate when it comes to optimal treatment. Clavicle fracture surgery has come a long way with excellent pre-contoured superior locking plates available for fixation. This study aimed to evaluate a cohort of patients operated for displaced mid-shaft clavicle fractures by open reduction and internal fixation using superior clavicle locking plates.

View Article and Find Full Text PDF

Purpose: Although open reduction and internal fixation (ORIF) is the gold standard treatment for displaced midshaft clavicle fractures, recent studies have advocated for nonoperative management, citing high rates of reoperation associated with operative intervention. However, no studies have compared nonoperative management to ORIF with dual-plate fixation, which may be associated with lower rates of reoperation compared to single-plate fixation. The purpose of this study was to compare the complications and patient-reported outcomes of dual mini-fragment plate fixation to nonoperative management for displaced midshaft clavicle fractures.

View Article and Find Full Text PDF

Background: Post-radiation fractures (PRF) are a recognised complication of radiation treatment for soft tissue sarcomas. They have a low incidence and typically occur up to 5 years following treatment, more commonly affecting the pelvis, ribs and femur. Due to radiation-induced changes in bone, PRFs typically require more complicated intervention compared to post-trauma fractures, however, limited literature exists, particularly in regards to mid-shaft femoral PRFs.

View Article and Find Full Text PDF

Background And Aims: The patellar tendon-bearing (PTB) brace is a crucial device designed to lessen axial forces on the tibia. The newly designed PTB brace allows clinicians to measure offloading amount in the realtime. This study aimed to explore the relationship between a rise in displacement between the foot plate and calf shells of this new PTB brace and changes in the amount of offloading on the tibia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!