A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Novel and Sensitive LC-MS/MS Method for the Quantitation of Ceftiofur in Pharmaceutical Preparations and Milk Samples. | LitMetric

A Novel and Sensitive LC-MS/MS Method for the Quantitation of Ceftiofur in Pharmaceutical Preparations and Milk Samples.

Comb Chem High Throughput Screen

Department of Analytical Chemistry, Faculty of Pharmacy, Anadolu University, 26470, Eskisehir, Turkey.

Published: October 2021

Introduction: In the present study, a sensitive and selective liquid chromatographytandem mass spectrometry (LC-MS/MS) method was described for the determination of ceftiofur (CEF) in cow milk and pharmaceutical preparations. CEF is an antibiotic compound, which is commonly used in the treatment of animal diseases such as respiratory system, soft tissue, and foot infections, as well as postpartum acute puerperal metritis. One of the critical features of CEF is its prescription while breastfeeding cows; in accordance, its quantitative estimation is essential to assess its residual amounts.

Methods: In the method reported herein, after simple protein precipitation using acetonitrile, the pre-treated samples were introduced into an LC-MS/MS instrument equipped with a Chromolith® High-Resolution RP-18 series HPLC column (100 mm × 4.6 mm from Merck KGaA, Germany). Electrospray ionization was employed as the ionization source in the triple-quadrupole tandem mass spectrometer.

Results: For the calibration method using solvent-based standards, LOQ was 3.038 ng/mL, 12.15 ng/mL, and LOD was 1.215 ng/mL and 6.076 ng/mL for ESI+ and ESI- modes, respectively. On the other hand, for the method of matrix-matched standards, LOQ was 1.701 ng/mL, 10.13 ng/mL, and LOD was 0.486 ng/mL and 5.929 ng/mL for ESI+ and ESI- modes, respectively as obtained from signal to noise ratio.

Conclusion: Applicability of both positive and negative ion modes was tested, and the analyte was detected via multiple reaction monitoring. The distorting effects of the milk matrix on the MS ionization and quantitation of CEF were overcome by using matrix-matched calibration for the first time.

Download full-text PDF

Source
http://dx.doi.org/10.2174/1386207323999201110192558DOI Listing

Publication Analysis

Top Keywords

lc-ms/ms method
8
pharmaceutical preparations
8
standards loq
8
ng/ml
8
1215 ng/ml
8
ng/ml lod
8
ng/ml esi+
8
esi+ esi-
8
esi- modes
8
method
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!