Laser-induced fluorescence (LIF) combined with multivariate techniques has been used in identifying antimalarial herbal plants (AMHPs) based on their geographical origin. The AMHP samples were collected from four geographical origins (Abrafo, Jukwa, Nfuom, and Akotokyere) in the Cape Coast Metropolis, Ghana. LIF spectra data were recorded from the AMHP samples. Utilizing multivariate techniques, a training set for the first two principal components of the AMHP spectra data was modeled through the use of K-nearest neighbor (KNN), support vector nachine (SVM), and linear discriminant analysis (LDA) methods. The SVM and KNN methods performed best with 100% success for the prediction data, while the LDA had a 99% success rate. The KNN and SVM methods are recommended for the identification of AMHPs based on their geographical origins. Deconvoluted peaks from the LIF spectra of all the AMHP samples revealed compounds such as quercetin and berberine as being present in all the AMHP samples.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/JOSAA.396701 | DOI Listing |
Aerosp Med Hum Perform
September 2024
Biomarker responses to intensive decompression indicate systemic proinflammatory responses and possible neurological stress. To further investigate responses, 12 additional brain and lung biomarkers were assayed. A total of 15 healthy men (20 to 50 yr) undertook consecutive same-day ascents to 25,000 ft (7620 m), following denitrogenation, breathing 100% oxygen.
View Article and Find Full Text PDFAerosp Med Hum Perform
December 2023
The present study examined long-term retention and transfer of knowledge and skills, as well as the effect of cognitive load on retention and transfer, using a sample of astronaut candidates and two comparison groups. The first comparison group, recruited from Johnson Space Center, was similar in age, education, and general health to the astronaut candidate group; the second comparison group included university undergraduate students.This study employed two different tasks-a simple perceptual-motor task involving data entry and a complex memory updating task requiring both prospective and retrospective memory.
View Article and Find Full Text PDFJ Thromb Haemost
April 2024
Coagulation Reference Laboratory, Department of Clinical Chemistry and Laboratory Medicine, Leiden University Medical Center, Leiden, the Netherlands.
Calibration of prothrombin time (PT) in terms of international normalized ratio (INR) has been outlined in "Guidelines for thromboplastins and plasmas used to control oral anticoagulant therapy" (World Health Organization, 2013). The international standard ISO 17511:2020 presents requirements for manufacturers of in vitro diagnostic (IVD) medical devices (MDs) for documenting the calibration hierarchy for a measured quantity in human samples using a specified IVD MD. The objective of this article is to define an unequivocal, metrologically traceable calibration hierarchy for the INR measured in plasma as well as in whole blood samples.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!